Поиск по всей станции

Газовый охлаждающий чиллер LQ -40°C~-110°C

LQ -40°C~-110°C

Semiconductor test chiller For non corrosive gas cooling
  • Мощность нагрева2.5кВт~25кВт
  • Мощность охлаждения0.25kW~25kW
  • Диапазон мощности6.5кВт~50кВт
  • Средняя точность±0.3℃
  • Давление потока20 л/мин ~ 150 л/мин 2,5 бар
  • ХладагентR404A/R508B

Загрузка данных о продукте

Подробные параметры

Модель LQ-4015 LQ-4030 LQ-4060 LQ-40100 LQ-7515 LQ-7530 LQ-7560 LQ-75100
LQ-4015W LQ-4030W LQ-4060W LQ-40100W LQ-7515W LQ-7530W LQ-7560W LQ-75100W
Поток газа 15 м3/ч 30 м3/ч 60m3/h 100m3/h 15 м3/ч 30 м3/ч 60m3/h 100m3/h
lowest temp. -40℃ -40℃ -40℃ -40℃ -75℃ -75℃ -75℃ -75℃
Площадь теплообмена 0.8m2 1.5m2 3m2 5m2 1.5m2 2.5m2 5m2 9m2
Материал теплообменника Standard configuration sus304 contains a small amount of copper
Gas inlet and outlet diameter G3/8 G1/2 G1 DN50 G3/8 G1/2 G1 DN50
Система управления Programmable controller and module
Отображение и запись 7-inch color touch screen, record curve temperature and alarm conditions
compressor France Taikang/Emerson Copeland
Электропитание 220V 50HZ 220V 50HZ 380V 50HZ 380V 50HZ 220V 50HZ 220V 50HZ 380V 50HZ 380V 50HZ
1,2 КВТ 1,8 КВТ 3,5 КВТ 7 КВТ 2 КВТ 3 КВТ 6 КВТ 11.5KW

Описание товара



It is used to cool the gas (non corrosive) or recover it as non corrosive gas by condensation and liquefaction.

Pressure resistance of gas heat exchange system: 25bar; The temperature range is – 40 ℃ ~ – 75 ℃, which can meet different temperatures;

The secondary subcooling technology is adopted, with rapid refrigeration and low refrigeration temperature;

Semi closed piston compressor, scroll flexible compressor and fully closed piston compressor of imported brands are adopted;

The evaporator adopts casing heat exchanger, which has the advantages of small volume, long residence time and high efficiency;

Danfoss expansion valve and Emerson electronic expansion valve are adopted, with high temperature control accuracy;

Siemens plcs7-200 / 300 and lneya touch screen display are used for automatic control operation;

The whole machine is installed. The system has been tested in the factory. Users only need to install the refrigerant pipeline and cooling water pipeline to run;

Factory test: each refrigeration unit shall be tested with load in the factory for no less than 12 hours;