Normal & Low Temperature Chillers -40℃~160℃
Control Temperature & Flow Systems
For Vehicle Components Testing,Hydrogen energy industry
Control temperature & flow system supports one to many, meaning that one refrigeration and heating temperature control flow host can control 2-6 different test benches or demand temperature control flow devices. Support two one to many modes, one is that temperature/flow/pressure can be independently controlled (T-series), and the other is that temperature is consistent across multiple groups, and flow/pressure is independently controlled (S-series).(LNEYA’s chiller supports both indoor and outdoor options.)
The automotive industry must ensure that its products operate over this wide temperature range and do not fail or material fatigue under rapid temperature changes.
Therefore, material and component testing, including temperature simulation, is very important and indispensable for the automotive industry, including all suppliers.
On the test benches in the automotive industry, highly dynamic temperature control systems are used for material and component testing, which can achieve precise regulation and rapid temperature changes. Only precise temperature management can provide reliable and repeatable results. The temperature control system provides a constant temperature or a complex temperature curve to the test bench directly or indirectly through a liquid medium. In addition to the temperature of the medium, temperature control systems also allow precise control of flow rates and operating pressures. Temperature control systems are used primarily in two ways: They simulate external ambient conditions in climate chambers or replace internal systems, such as the cooling circuit of an engine. The latter allows realistic conditions to be created on test benches, where test specimens are supplied with coolant according to operational requirements, such as in a vehicle.
Мы поставляем нашим клиентам в автомобильной промышленности высокопроизводительные устройства. Они не только динамически охватывают весь диапазон температур от -40°C до +160°C и быстро меняют температуру на испытательных стендах.
KRY series advantages
Эффективная стабильность производства и повторяемость результатов;
Использование пластинчатых теплообменников и трубопроводных нагревателей для повышения скорости охлаждения и нагрева;
Очень широкий диапазон температур, нет необходимости заменять жидкую среду;
Полностью закрытая система, продлевающая срок службы теплопроводных жидкостей;
Благодаря магнитному приводу насоса отсутствует проблема утечки уплотнения вала;
LOW TEMPERATURE SERIES
KRY -20℃~+100℃
Модель |
KRY-255 KRY-255W |
KRY-275 KRY-275W |
KRY-2A10 KRY-2A10W |
KRY-2A15 KRY-2A15W |
KRY-2A25 KRY-2A25W |
KRY-2A38W |
Диапазон температур |
-20℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Выходной сигнал расхода |
1~15 L/min |
1~25 L/min |
1~30 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Точность расхода |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
Мощность нагрева |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
Мощность охлаждения |
100℃ |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
20℃ |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
0℃ |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
-15℃ |
2,8 кВт |
3,8 кВт |
4,6 кВт |
7 кВт |
12 кВт |
16 кВт |
Размер соединения |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
Water-cooled type W at 25℃ |
1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000 Л/ЧАС ZG1 |
6000 Л/ЧАС DN32 |
9000 Л/ЧАС DN40 |
Мощность 380V50HZ |
11 кВт |
14 кВт |
19 кВт |
23 кВт |
31kW |
45 кВт |
Размер см |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
Вес |
230 кг |
250 кг |
300 кг |
320 кг |
570 кг |
830 кг |
Дополнительно |
Расширить до -40 ~ +135℃ |
KRY -40℃~+100℃
Модель |
KRY-455 KRY-455W |
KRY-475 KRY-475W |
KRY-4A10 KRY-4A10W |
KRY-4A15 KRY-4A15W |
KRY-4A25 KRY-4A25W |
KRY-4A38W |
KRY-4A60W |
Диапазон температур |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Выходной сигнал расхода |
1~25 L/min |
1~25 L/min |
1~25 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Точность расхода |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
Мощность нагрева |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
60 кВт |
Мощность охлаждения |
100℃ |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
60 кВт |
20℃ |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
60 кВт |
0℃ |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
60 кВт |
-20℃ |
2,8 кВт |
4,5 кВт |
6 кВт |
10 кВт |
16 кВт |
25 кВт |
35 кВт |
-35℃ |
1,2 кВт |
1,8 кВт |
2,5 кВт |
4 кВт |
6,5 кВт |
10 кВт |
15 кВт |
Размер соединения |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
Water-cooled type Wat25度 |
1900L/H ZG3/4 |
2500L/H ZG3/4 |
3000L/H ZG1 |
4000 Л/ЧАС ZG1 |
6000 Л/ЧАС DN32 |
9000 Л/ЧАС DN40 |
15000 Л/ЧАС DN50 |
Мощность 380V50HZ |
10 кВт |
14 кВт |
17 кВт |
25 кВт |
38 кВт |
58kW |
84kW |
Размер см |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
200*145*205 |
Вес |
250 кг |
280 кг |
320 кг |
360 кг |
620 кг |
890 кг |
1300 КГ |
Дополнительно |
Расширить до -40 ~ +135℃ |
KRY -40℃~+100℃ 2T
Модель |
KRY-475/2T KRY-475W/2T |
KRY-4A15W/2T |
KRY-4A25W/2T |
KRY-4A38W/2T |
KRY-4A60W/2T |
Диапазон температур |
-40℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Точность контроля расхода/группа |
1~25 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
Number of fuid output groups |
2 groups |
2 groups |
2 groups |
2 groups |
2 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Мощность нагрева |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
Мощность охлаждения |
100℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
20℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
0℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
-20℃ |
4.5kW*2 |
8.5kW*2 |
14kW*2 |
22kW*2 |
35kW*2 |
-35℃ |
1.8kW*2 |
4kW*2 |
6.5kW*2 |
10kW*2 |
15kW*2 |
Water-cooled type Wat 20度 |
4000 Л/ЧАС ZG1 |
8000 Л/ЧАС DN32 |
12000 Л/ЧАС DN40 |
20000L/H DN50 |
30000L/H DN65 |
Размер см |
28 кВт |
45 кВт |
70kW |
108kW |
158kW |
Water-cooled cm |
80*100*185 |
100*150*185 |
200*145*205 |
200*145*205 |
250*145*225 |
Вес |
660KG |
850KG |
1350KG |
1800KG |
2600 КГ |
Дополнительно |
Расширить до -40 ~ +135℃ |
KRY -20℃~+100℃ 6S
Модель |
KRY-2A25W/6S |
KRY-2A38W/6S |
KRY-2A60W/6S |
Диапазон температур |
-20℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Точность контроля расхода/группа |
1~25 L/min |
1~25 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
Number of fuid output groups |
6 групп |
6 групп |
6 групп |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Мощность нагрева |
15 кВт |
25 кВт |
38 кВт |
Мощность охлаждения |
100℃ |
25 кВт |
38 кВт |
60 кВт |
20℃ |
25 кВт |
38 кВт |
60 кВт |
0℃ |
25 кВт |
38 кВт |
60 кВт |
-15℃ |
10 кВт |
15 кВт |
24 кВт |
Water-cooled type Wat 20度 |
8000 Л/ЧАС DN40 |
12000 Л/ЧАС DN50 |
20000L/H DN65 |
Мощность 380V50HZ |
36 кВт |
51 кВт |
75 кВт |
Water-cooled cm |
200*145*205 |
200*145*205 |
200*145*205 |
Вес |
900 кг |
1100 кг |
1750 кг |
KRY -40℃~+100℃ 6S
Модель |
KRY-4A25W/6S |
KRY-4A38W/6S |
KRY-4A60W/6S |
Диапазон температур |
-40℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Точность контроля расхода/группа |
1~25 L/min |
1~25 L/min |
1~40 L/min |
Flow rate accuracy/group |
±0,2 л/мин |
±0,2 л/мин |
±0,2 л/мин |
Number of fuid output groups |
6 групп |
6 групп |
6 групп |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Мощность нагрева |
15 кВт |
25 кВт |
38 кВт |
Мощность охлаждения |
100℃ |
25 кВт |
38 кВт |
60 кВт |
20℃ |
25 кВт |
38 кВт |
60 кВт |
0℃ |
25 кВт |
38 кВт |
60 кВт |
-20℃ |
14 кВт |
22 кВт |
35 кВт |
-35℃ |
5 кВт |
8 кВт |
13 кВт |
Water-cooled type Wat 20度 |
8000 Л/ЧАС DN40 |
12000 Л/ЧАС DN50 |
18000L/H DN65 |
Мощность 380V50HZ |
38 кВт |
55 кВт |
82 кВт |
Размер см |
200*145*205 |
200*145*205 |
200*145*205 |
Вес |
900 кг |
1200kg |
1950kg |
Дополнительно |
Расширить до -40 ~ +135℃ |
NORMAL TEMPERATURE SERIES
KRY 0℃~+100℃
Модель |
KRY-25 |
KRY-55 |
KRY-75 |
KRY-A10 |
KRY-A15 KRY-A15W |
KRY-A25 KRY-A25W |
KRY-A38W |
KRY-A60W |
Диапазон температур |
0℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Выходной сигнал расхода |
2~20 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
5~50 L/min |
5~50 L/min |
Точность расхода |
±0,2 л/мин |
Мощность нагрева |
2,5 кВт |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
15 кВт |
25 кВт |
38 кВт |
Мощность охлаждения |
100℃ |
2,5 кВт |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
60 кВт |
20℃ |
2,5 кВт |
5,5 кВт |
7,5 кВт |
10 кВт |
15 кВт |
25 кВт |
38 кВт |
60 кВт |
5℃ |
1,8 кВт |
3,8 кВт |
5,2 кВт |
7 кВт |
11 кВт |
18 кВт |
27 кВт |
42 кВт |
Размер соединения |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
G3/4 |
Water-cooled type Wat25度 |
|
|
|
|
3200 Л/ЧАС ZG1 |
6000 Л/ЧАС G1 1/4 |
9000 Л/ЧАС DN40 |
15000 Л/ЧАС DN50 |
Мощность 380V50HZ |
4,5 кВт220 В |
8,5 кВт |
11,5 кВт |
16 кВт |
18 кВт |
28 кВт |
40 кВт |
61 кВт |
Размер см |
50*85*145 |
55*100*175 |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
100*150*185 |
Вес |
220kg |
250 кг |
280 кг |
320 кг |
360 кг |
620 кг |
890 кг |
1300 КГ |
KRY 0℃~+100℃ 2T
Модель |
KRY-25/2T |
KRY-55/2T |
KRY-75/2T |
KRY-A10/2T |
KRY-A15W//2T |
KRY-A25W/2T |
KRY-A38W/2T |
KRY-A60W/2T |
Диапазон температур |
0℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
0.01k |
Выходной сигнал расхода |
2~20 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
2~25 L/min |
5~50 L/min |
5~50 L/min |
Точность расхода |
±0,2 л/мин |
Мощность нагрева |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
Мощность охлаждения |
100℃ |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
20℃ |
2.5kW*2 |
5.5kW*2 |
7.5kW*2 |
10kW*2 |
15kW*2 |
25kW*2 |
38kW*2 |
60kW*2 |
5℃ |
1.8kW*2 |
3.8kW*2 |
5.2kW*2 |
7kW*2 |
11kW*2 |
18kW*2 |
27kW*2 |
42kW*2 |
Размер соединения |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
ZG3/4 |
Water-cooled type Wat25度 |
|
|
|
|
5600L/H DN32 |
10000L/H DN40 |
17000L/H DN50 |
24000L/H DN65 |
Мощность 380V50HZ |
9 кВт |
19 кВт |
23 кВт |
29kW |
34 кВт |
52 кВт |
80kW |
120 кВт |
Размер см |
55*100*175 |
70*100*175 |
80*120*185 |
100*150*185 |
100*150*185 |
200*145*205 |
200*145*205 |
250*145*225 |
Вес |
260KG |
320 КГ |
400 КГ |
580KG |
750KG |
1250KG |
1600KG |
2400KG |
KRY 0℃~+100℃ 6S
Модель |
KRY-A25W/6S |
KRY-A38W/6S |
KRY-A60W/6S |
Диапазон температур |
0℃~+100℃ |
Точность регулирования температуры |
±0.3℃ |
±0.3℃ |
±0.3℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Точность контроля расхода/группа |
2~25 L/min |
2~25 L/min |
2~25 L/min |
Flow rate accuracy/group |
±0,2 л/мин |
Number of fuid output groups |
6 групп |
6 групп |
6 групп |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Мощность нагрева |
15 кВт |
25 кВт |
38 кВт |
Мощность охлаждения |
100℃ |
25 кВт |
38 кВт |
60 кВт |
20℃ |
25 кВт |
38 кВт |
60 кВт |
5℃ |
18 кВт |
27 кВт |
42 кВт |
Water-cooled type Wat 20度 |
6000 Л/ЧАС DN32 |
9000 Л/ЧАС DN40 |
15000 Л/ЧАС DN50 |
Мощность 380V50HZ |
38 кВт |
55 кВт |
82 кВт |
Размер см |
200*145*205 |
200*145*205 |
200*145*205 |
Вес |
900 кг |
1200kg |
1950kg |
Frequency Conversion Series
KRYZ -40℃~+100℃
Модель |
KRYZ-475 KRYZ-475W |
KRYZ-4A15W |
KRYZ-4A25W |
Диапазон температур |
-40℃~+100℃ |
-40℃~+100℃ |
-40℃~+100℃ |
Точность регулирования температуры |
±0.1℃ |
±0.1℃ |
±0.1℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Выходной сигнал расхода |
1~25 L/min |
1~25 L/min |
1~25 L/min |
Точность расхода |
±0.1 L/min |
±0.1 L/min |
±0.1 L/min |
Мощность нагрева |
7,5 кВт |
15 кВт |
25 кВт |
Охлаждение емкость |
100℃ |
7,5 кВт |
15 кВт |
25 кВт |
20℃ |
7,5 кВт |
15 кВт |
25 кВт |
0℃ |
7,5 кВт |
15 кВт |
25 кВт |
-20℃ |
4,5 кВт |
10 кВт |
16 кВт |
-35℃ |
1,8 кВт |
4 кВт |
6,5 кВт |
Размер соединения |
G3/4 |
G3/4 |
G3/4 |
Водяное охлаждение At20℃ |
2500L/H ZG3/4 |
4000 Л/ЧАС ZG1 |
6000 Л/ЧАС DN32 |
Мощность 380V50HZ |
14 кВт |
25 кВт |
38 кВт |
Размер см |
55*85*175 |
70*100*175 |
80*120*185 |
Вес |
280 кг |
360 кг |
620 кг |
Дополнительно |
Extended to -40 ℃~+135 ℃ |
KRYZ -40℃~+100℃ 2T
Модель |
KRYZ-475W/2T |
KRYZ-4A15W/2T |
KRYZ-4A25W/2T |
Диапазон температур |
-40℃~+100℃ |
Точность регулирования температуры |
±0.1℃ |
±0.1℃ |
±0.1℃ |
Обратная связь по температуре |
Pt100 |
Pt100 |
Pt100 |
Temp display |
0.01k |
0.01k |
0.01k |
Выходной сигнал расхода |
1~25 L/min |
1~25 L/min |
1~25 L/min |
Точность контроля расхода/группа |
±0.1 L/min |
±0.1 L/min |
±0.1 L/min |
Number of fuid output groups |
2 groups |
2 groups |
2 groups |
Pressure control/group |
0.2bar~2.5bar |
0.2bar~2.5bar |
0.2bar~2.5bar |
Мощность нагрева |
7.5kW*2 |
10kW*2 |
15kW*2 |
Охлаждение емкость |
100℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
20℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
0℃ |
7.5kW*2 |
15kW*2 |
25kW*2 |
-20℃ |
4.5kW*2 |
8.5kW*2 |
14kW*2 |
-35℃ |
1.8kW*2 |
4kW*2 |
6.5kW*2 |
Водяное охлаждение At20℃ |
4000 Л/ЧАС ZG1 |
8000 Л/ЧАС DN32 |
12000 Л/ЧАС DN40 |
Размер см |
80*120*185 |
100*150*185 |
200*145*205 |
Мощность 380V50HZ |
28 кВт |
45 кВт |
70kW |
Вес |
660KG |
850 кг |
1350kg |
Дополнительно |
Extended to -40 ℃~+135 ℃ |
Hourly power consumption kWh |
-40℃ |
-10℃ |
20℃ |
KRY-475 |
5 |
6.2 |
8.4 |
KRYZ-475 |
2.2 |
4 |
4.8 |
Frequency conversion saves power consumption |
56% |
35% |
43% |
Explain |
1. Empty load test data; 2. The test condition is an ambient temperature of 20 ℃; 3. Flow rate 15L/min |
Oil cooling chiller for motor test
KRYZ 0℃~+160℃
Модель |
KRYO-A15W |
KRYO-A25W |
KRYO-A38W |
KRYO-A15W2S |
KRYO-A25W2S |
KRYO-A38W2S |
Диапазон температур |
0℃ ~ +160℃ Different viscosity oils have different temperature ranges |
Точность регулирования температуры |
±0.3℃ |
Точность расхода |
±0,2 л/мин |
Контроль давления |
0.2bar~2.5bar |
Мощность нагрева |
15 кВт |
25 кВт |
38 кВт |
15 кВт |
25 кВт |
38 кВт |
Охлаждение емкость |
125℃ |
15 кВт |
25 кВт |
38 кВт |
15 кВт |
25 кВт |
38 кВт |
20℃ |
12 кВт |
20 кВт |
30 кВт |
12 кВт |
20 кВт |
30 кВт |
Хладагент |
R410A |
Вторичный хладагент |
Масло |
Размер соединения |
G3/4 |
Водяное охлаждение At20℃ |
3000L/H |
4200 Л/ЧАС |
6200L/H |
3000L/H |
4200 Л/ЧАС |
6200L/H |
Размер соединения |
G3/4 |
G3/4 |
G1 |
G3/4 |
G3/4 |
G1 |
direct cooling heating series
Can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output;
KRYZ 0℃~+160℃
Модель |
KRYZ-5W-ZLH |
KRYZ-5W-ZL |
KRYZ-5-ZLH |
KRYZ-5-ZL |
Мощность охлаждения |
0.5kW~10kW |
0.5kW~10kW |
Мощность нагрева |
0.5kW~10kW |
|
Undercooling degree |
Refrigeration 0k~8K Heating at 0k~6k in low-temp environment, 6k~20k |
Refrigeration 0k~8K |
Overheating degree |
Refrigeration 2k~20k Heating 2k~10k |
Refrigeration 2k~20k |
Condensation pressure control accuracy |
Better than ±50kpa |
Better than ±50kpa |
Suction pressure |
300kpa~600kpa ±10kpa |
300kpa~600kpa ±10kpa |
Battery pack testing environment Temp |
-40℃~50℃ |
-40℃~50℃ |
multi-channel independent temperature control
Adopts LNEYA PLC control, simple menu navigation, 7″ color large screen, multi-faceted and multi-functional images to display comprehensive important data information. The newly added safety measures ensure continuous unattended operation. All relevant operating status data are continuously monitored and visualized on the touch screen. Supports one-to-many multi-channel independent control, and each group can be set independently.
Appearance details
Application cases
Испытательный прибор должен использовать специальные кривые изменения температуры и регистрировать изменения температуры; диапазон температур обычно составляет от -40 ℃ до 100 ℃ (может расширяться до 150 ℃); при проведении испытаний на допуск, как правило, выполняется в бесконечном цикле.
High adaptability and wide applicationS
Suitable for more simulation test temperature control
Equipment application: new energy battery pack, battery module, battery cell, motor and controller, charger, DC/DC converter, electronic pump
ЗАПРОСИТЬ ЦЕНУ
Рекомендуемые продукты
Контроль температуры :-5℃~-150℃
Регулирование температуры для различных реакторов, систем дистилляции или экстракции, лабораторий, научно-исследовательских институтов, химической, фармацевтической, нефтехимической, биохимической, медицинской промышленности, больниц, научно-исследовательских и опытно-конструкторских мастерских, испытаний полупроводников, аэрокосмической промышленности, биологии.
Контроль температуры :-120℃~350℃
Контроль температуры для реактора высокого давления; Двухслойный стеклянный реактор; Двухслойный реактор; Микроканальный реактор; Система дистилляции; Испытание на старение материала; Вакуумная камера и т. д.
Контроль температуры: -40℃ ~ 100℃
Моделирование температуры для проверки качества автомобиля: проверка срока службы аккумулятора, стенд для проверки топливных форсунок/двигателей, проверка подушек безопасности, стенд для проверки компонентов и т.д. Он может имитировать внешние условия окружающей среды в климатической камере или заменить внутреннюю систему, которая может создать необходимые фактические температурные условия для испытательного стенда.
Контроль температуры: -85℃ ~ 250℃
Suitable for semiconductor process wet washing, photolithography, etching, chemical meteorological deposition, physical meteorological deposition, and the electronics industry (photolithography process)