Precautions for Leakage Inspection of Glycol Ch...

Precautions for Leakage Inspection of Glycol Chiller

2024-03-19

The main points about checking leakage of glycol chillerDuring the operation of the glycol chiller, it is critical that the refrigeration system does not leak. In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy wate...

Посмотреть детали
Operating instructions for the chiller, a labor...

Operating instructions for the chiller, a laboratory process temperature control cycle system

2024-03-19

The heat transfer medium of the laboratory process temperature control circulation system chiller uses oil and water. It uses electric heating to heat the heat transfer medium (heat transfer oil or water) that is forced to circulate in the pipeline under the action of the pump, and transfers heat energy through heat exchange. And can automatically adjust the temperature to achieve the purpose of accurate temperature control. 1. The installation is simple, the operation is simple, and no profe...

Посмотреть детали
Как продлить срок службы гликолевого охладителя...

Как продлить срок службы гликолевой системы охлаждения?

2024-03-19

Чтобы продлить срок службы вашего гликолевого охладителя в промышленных условиях, обратите внимание на следующие моменты- 1. Осторожно используйте автомобильный антифризНе используйте автомобильный или неквалифицированный антифриз. Поскольку такой гликоль не предназначен для промышленного применения, он может вызвать различные проблемы и сократить срок службы вашей системы гликолевого охладителя. 2. Соблюдайте местные правила. Эксперты разработали различные правила и нормы в соответствии с...

Посмотреть детали
Tips for shutting down the industrial chiller f...

Tips for shutting down the industrial chiller for temperature control of the reactor

2024-03-19

Industrial chillers are equipped with a wide range of accessories and equipment. In actual use, it is necessary to provide regular rest time for industrial chillers. In order to maintain stable performance during long-term operation, users need to master the actual use needs. The method of shutting down the industrial chiller to reduce problems such as excessive wear and tear of the equipment. Method for shutting down the industrial chiller of the reactor temperature control unit: 1. When the...

Посмотреть детали
Solution to High and Low Pressure Fault of Wate...

Solution to High and Low Pressure Fault of Water Cooled Chiller

2024-03-19

The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of water-cooled chiller. The reason can be preliminarily identified as poor water quality, and corresponding impurities (leaves, weeds, etc.) enter the water distribution hole, which affects the heat dissipation of the cooling water tower. Next, I will i...

Посмотреть детали
Heat transfer oil chemical temperature control ...

Heat transfer oil chemical temperature control system product application

2024-03-19

The heat transfer oil heating and cooling temperature control system is a device with heating or lowering at the same time, that is, when the temperature of the equipped glass reactor, rotary evaporator, extraction equipment and other devices needs to be raised or lowered rapidly to reach the set temperature. The heating and cooling of the equipment can be changed quickly, and the medium (heat-conducting oil) used is the same medium, which improves the disadvantage that two different instrume...

Посмотреть детали
Performance Characteristics of 30 HP Water Cool...

Performance Characteristics of 30 HP Water Cooled Chiller

2024-03-19

The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for cooling, which has some requirements for the environment: for example, ventilation, humidity and temperature cannot be higher than 40 ℃, air pH value, etc. Performance characteristics of 30p water-cooled industrial chiller: 1. The primary effect filter ...

Посмотреть детали
Instructions for the use of temperature control...

Instructions for the use of temperature control equipment for isolation reactors

2024-03-19

The reaction kettle is a commonly used reactor in pharmaceutical and chemical production. The temperature control equipment of the isolated reaction kettle is realized by controlling two doors, namely the heating water valve and the cooling water valve. make it even temperature. The temperature of the isolation reaction kettle is controlled in the heating stage, the heating water valve is opened, and the coil pipe in the kettle is connected with heating water, so that the temperature rises, a...

Посмотреть детали
Cause Analysis of Poor Cooling Effect of Water ...

Cause Analysis of Poor Cooling Effect of Water Cooled Chiller

2024-03-19

Water cooled chillers have been more and more widely used in all walks of life around us. Its main function is to provide industrial chilled water for equipment or products. The water temperature range can be adjusted according to users' needs, and its accuracy can be accurately controlled at ±1℃. However, in the process of using the chiller, some users encounter the situation that the temperature cannot drop. Let's analyze it together. The poor cooling effect of water cooled chillers is main...

Посмотреть детали
Precautions for installation of special chiller...

Меры предосторожности при установке специального охладителя для испытания новой энергии

2024-03-19

The installation of the special chiller for new energy testing is an important link before operation. The quality of the installation is directly related to the operation and operation status of the special chiller for new energy testing. So, what should be paid attention to in the installation of the special chiller for new energy testing? If the special chiller for new energy test adopts semi-hermetic or fully-hermetic compressor, an oil separator should be installed, and an appropriate amo...

Посмотреть детали