Tips for shutting down the industrial chiller for temperature control of the reactor
Industrial chillers are equipped with a wide range of accessories and equipment. In actual use, it is necessary to provide regular rest time for industrial chillers. In order to maintain stable performance during long-term operation, users need to master the actual use needs. The method of shutting down the industrial chiller to reduce problems such as excessive wear and tear of the equipment.

Method for shutting down the industrial chiller of the reactor temperature control unit:
1. When the chiller for industrial reactor needs to be shut down, it is necessary to first consider the shutdown range of the chiller before all shutdown operations can be performed. In order to avoid generating a large pressure, the user needs to close the suction shut-off valve to stop the operation of the compressor.
2. After closing the chiller compressor, it is necessary to operate the oil pump. Return the slide valve of the industrial single-reactor chiller to the 0-scale position, so that the load reduction reaches zero, and the oil pump will immediately stop all operations.
3. The chiller is used for a single industrial reactor, and the operation of the water pump and the cooling water tower needs to be stopped in the latter step. After such equipment is stopped, the entire power supply of the industrial single reactor freezer can be turned off, and the entire shutdown process of the industrial ice water machine can be completed. Ensure that the industrial chiller for a single reactor is in a shutdown state.
Precautions:
1. If the machine is shut down for a long time, it is necessary to carry out special treatment for the industrial single reactor chiller. Including the condenser and the evaporator, it is necessary to completely pump the refrigerant to the condenser, and at the same time discharge all the water sources to avoid problems such as corrosion.
2. After the shutdown is completed, it is necessary to carry out detailed inspections for various accessories. The shutdown process is more particular, and the use of the shutdown steps can prolong the service life of the equipment.
Summarize:
For the chiller for industrial single reactor that has been shut down for a long time, it is necessary to carry out careful testing to ensure that the equipment is kept away from various corrosive substances, and to improve the shutdown performance of the chiller for industrial single reactor.
Похожие рекомендации
-
Шнековый чиллер с шумом должен быть своевременно проверен и отремонтирован
1032Before we use an industrial screw chiller factory, we will check all aspects of it, such as parts inspection, configuration, noise, and so on. What should I do if there is noise in the screw chiller during use? Do I need someone to repair it? The ...
Посмотреть детали -
Как хладагент устанавливается в конденсаторный агрегат vocs?
1268The vocs condensing equipment is LNEYA's equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated? For various refrigeratio...
Посмотреть детали -
Is the centrifugal pump or the volumetric pump selected in the pharmaceutical laboratory?
975In the pharmaceutical laboratory, a variety of refrigeration equipment is used more, then as a more common equipment - pumps, mainly centrifugal pumps, volumetric pumps. Then, the user friend should have a better understanding of their performance...
Посмотреть детали -
What should I pay attention to when using the reactor for chilling and cooling?
1131When using the reactor chilling and cooling and cooling device, users need to pay attention to their refrigeration and heating operations. Pay attention to the operation within a reasonable temperature range to avoid excessive temperature and pres...
Посмотреть детали