What aspects need to be considered in the external circulation cooling system of the test bench?

As we all know, the test room needs to be equipped with a cooling system for vehicle performance and comprehensive transmission, road simulation, electromagnetic compatibility, power battery, vehicle environment and other tests.
In the automobile inspection test, the inspection of the engine is an important task, so how to design the cooling system of the test bench for the inspection of the engine, especially the diesel engine?
When the diesel engine is working, high temperature will cause wear and tear of parts and oil aging, which will restrict the service life of the diesel engine, so cooling is one of the key systems, but the cooling should not be excessive, which will cause rough work, high oil viscosity, and low mechanical efficiency, so the appropriate cooling degree is better .
For the design of the circulating cooling water system of the test bench, the cooling process should be reasonable, the water supply should be sufficient, the water return should be smooth, and the water flow and water pressure should be reasonably controlled.
1. To determine the amount of cooling water
To calculate the amount of cooling water, five factors should be considered: the calorific value of the engine under standard operating conditions, the calorific value of the maximum operating conditions, the proportion of heat taken away by cooling water and engine oil, the number of test rooms, and the total cooling efficiency and loss.
2. Formulate water supply and return water plan
The whole water supply system is generally composed of common water pumps and spare pumps. The flow of the pumps is adjusted by the amount of water required for the engine bench test, and the operation is controlled automatically. The return water system adopts pressure return water.
3 Refrigeration system design and selection
4 Design and construction of hot and cold water pools
5 water treatment device
The above content comes from the Internet and combined with the description of the supporting use of the product. If you have any questions, please contact us. Thanks!
Похожие рекомендации
-
Описание высокоточной системы контроля температуры Lneya Semiconductor
1366В настоящее время в полупроводниковой промышленности выпускаются высокоточные системы температурного контроля с очень сложными характеристиками. Здесь представлено описание полупроводниковой высокоточной системы контроля температуры.
Посмотреть детали -
Уси Гуанья (LNEYA): Десять лет ветра и дождя, весь путь
860Для компании Wuxi Guanya LNEYA успех никогда не был достигнут в одночасье. За время развития компании Wuxi Guanya, после более чем десяти лет взлетов и падений, были достигнуты блестящие успехи в области охлаждения и контроля температуры нагрева. Это...
Посмотреть детали -
Инструкция по эксплуатации испарителя большого промышленного холодильника
1207В процессе эксплуатации большого промышленного холодильника Wuxi Guanya LNEYA, из-за большого количества деталей и сложности, нам необходимо разобраться в работе компонентов больших промышленных холодильников. Испаритель является одним из основных к...
Посмотреть детали -
На какие аспекты следует обратить внимание при использовании лабораторных криогенных холодильных циркуляторов?
1027Компактный циркуляционный охладитель - экономичная модель для рутинных лабораторных приложений. Прибор охлаждается в диапазоне температур от -10 или 0°C до +40°C, а точность контроля температуры может достигать ±0,5°C. Это хороший способ заменить э...
Посмотреть детали