What are the advantages and disadvantages of thermal oil heating circulators?

The heat conduction oil heating circulator adopts a fully closed loop structure to directly act on the heat energy to the heated medium.
Its advantages are:
(1) Due to the continuous renewal of the heat transfer surface, the heat loss is small;
(2) The temperature field distribution state of the medium can be changed during operation;
(3) Multiple units can be used in parallel. The closed circulation system has a wide range of applications, such as various boilers, industrial furnaces, air preheaters, dryers, ovens and other places that require heat transfer.
But it also has many shortcomings, mainly as follows:
(1) Air resistance is easy to occur when there is gas or liquid in the system;
(2) It is not easy to realize automatic control and remote control;
(3) It is difficult to adapt to high temperature and high pressure occasions.
LNEYA’s thermal oil heating circulator adopts the complete cooling process to achieve 300°C~50°C cooling, which can continuously increase and decrease the temperature. There is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned. It has the function of correcting the internal circulation temperature probe PT100. With safety protection functions, such as self-diagnosis, high-voltage pressure switch, overload relay, thermal protection device, etc. When the system is running, the pressure will not increase due to high temperature, and the heat transfer medium will be automatically replenished at low temperature.
Похожие рекомендации
-
Motor test bench test and temperature system for vehicle components
1375All vehicle components must undergo rigorous testing, but safety programs must undergo more stringent durability and terminal testing. Many physical methods can be used to load the motor, but the small motor test bench is favored for its high spee...
Посмотреть детали -
Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
1204Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chil...
Посмотреть детали -
Принципиальный анализ гликолевого чиллера
1111Гликолевый чиллер - это промышленный чиллер с гликолем в качестве хладагента. Структура гликолевого чиллера примерно такая же, как и у обычного промышленного чиллера, который состоит из компрессора, испарителя, конденсатора и электрической системы управления. ...
Посмотреть детали -
LNEYA temperature control system AH series commentary
1143Refrigeration heating temperature control system AH series, suitable for high heat release, suitable for SUS reactor, temperature difference > 150 ° C, can quickly cool high temperature reaction, polymerization reaction and rapid heating and co...
Посмотреть детали