How does the cooling and heating system achieve simultaneous temperature control?
Temperature control system The thermostat has heating and cooling functions, and can use the same medium for continuous temperature control from -120℃~320℃.
The heating and cooling system of cooling and heating system is mainly composed of four parts: heat exchanger, compressor, evaporator and condenser, and it is also one of the very key components of the whole high and low temperature integrated machine. The heat exchanger is mainly to transfer heat from the hot fluid to the cold fluid, the heat exchanger has a four-way valve, which can cool the heat exchanger. The condenser is part of the cooling system of the high and low temperature all-in-one machine, which converts gas or vapor into liquid, and can transfer the heat in the pipe to the nearby air. The evaporator is one of the very important components of refrigeration. The low-temperature condensate exchanges heat with the outside air through the evaporator, and evaporates to absorb heat. The evaporator is mainly composed of a heating chamber and an evaporation chamber. The heating chamber provides the heat needed to evaporate the liquid to promote boiling and evaporation of the liquid.
The cooling and heating system is suitable for equipment connected to reaction devices for refrigeration and heating reactions in the pharmaceutical and chemical industries. There are many production steps that require reliable temperature control as part of prototyping equipment. The working principle is to drive the heat transfer medium (usually water, ethanol, silicone oil, etc.) from the oil tank with built-in heater to the temperature control equipment through the pump, and then return to the oil tank from the temperature control equipment. The controller adjusts the temperature of the thermal fluid to adjust the temperature of the temperature control device according to the temperature of the thermal fluid measured by the temperature sensor or the internal temperature of the temperature control device. In recent years, there have been more and more applications in the chemical industry. After purchasing the high and low temperature cycle machine, it is necessary to carry out actual operation, but many users are not very familiar with its main operation. If the operation is not performed according to the requirements, it will not only affect the performance and life of the equipment, but may even be dangerous. Accidents happen.
Похожие рекомендации
-
Меры предосторожности при замене холодильного масла в системе охлаждения зарядного устройства автомобиля
1627Во время работы системы охлаждения бортового зарядного устройства необходимо обращать внимание на состояние холодильного масла. После запуска компрессора внимательно следите за изменением температуры и давления масла. Если температура масла меняется...
Посмотреть детали -
Description of the action of the filter in the ultra-low temperature compressor unit
1765In order to stabilize the operation of the ultra-low temperature compressor unit, the performance of the compressor is very important, and in addition to the compressor, the filter is also important. In order to maintain normal operation, it is ne...
Посмотреть детали -
The role of recirculating heaters in chemical and biological reaction instruments
1302Temperature Control: The recirculating heater provides a precise and stable temperature control environment, which is a crucial factor in chemical and biological reactions. Different chemical reactions and biological processes have spec...
Посмотреть детали -
Как выбрать охладитель с водяным охлаждением винтового типа
1932По сравнению с аналогичными чиллерами, винтовой тип чиллера с водяным охлаждением имеет много преимуществ. Мы, как один из ведущих производителей чиллеров, поделимся с вами. 1. Температура теплопроводящей жидкости может быть отрегулирована до любой температуры, которую вы хотите, а...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик