Semiconductor refrigeration temperature control table cooler operation instructions
The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching between the active and standby working power sources. When the common power failure occurs, it automatically switches to the standby power supply. When both power supplies are normal, the common power supply works and the standby power supply is in standby state. The semiconductor refrigeration temperature control station programmable controller (PLC) is the control center of the execution part of the strong oil air cooler control device. It receives various status signals from the transformer to control the execution part.
When the transformer of the semiconductor refrigeration temperature control console is put into operation, a group of coolers will be put into operation, that is, the working group cooler is operated. The auxiliary cooler is controlled according to the oil surface temperature of the transformer, the winding temperature, the load signal, etc., and the auxiliary cooler can be activated as follows. The cooling method of the semiconductor refrigeration temperature control transformer is forced oil circulation air cooling, and at least one group of coolers should be operated after the transformer is put into operation. The control box of the semiconductor refrigeration temperature control station is controlled by intelligent equipment, and the cooling device for controlling the transformer is mainly controlled by a main switch such as a change switch on the control panel.

The structure and operation description of the semiconductor refrigeration temperature control station are as shown above. When the user operates the semiconductor refrigeration temperature control station, the operating efficiency of each component is ensured as much as possible, so that the overall operating efficiency of the semiconductor refrigeration temperature control station can be improved.
Похожие рекомендации
-
Что делать при срабатывании сигнализации высокого давления в холодильнике
1319Люди должны обращать внимание на обслуживание крупномасштабного оборудования для контроля температуры, такого как промышленный охладитель воды. Иногда нормально столкнуться с аварийным сигналом высокого давления. Сначала необходимо выяснить причины высокого давления в промышленном...
Посмотреть детали -
Failures of Heating Cooling Circulators
990The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator?Failure of circulating pumpThe failure of the circulating pump is generally the heat ov...
Посмотреть детали -
Reactor Thermal Control Unit and Solutions for Chemicals
1415Temperature control is a process in which the temperature of a substance or a change in temperature is measured or otherwise detected, and the transfer of thermal energy into or out of the space or substance is adjusted to achieve the desired temp...
Посмотреть детали -
Why is there air in the reactor temperature control system?
969The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the powe...
Посмотреть детали