Reasons for the decrease of heat transfer effect of vertical ultra-low temperature refrigerator
If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 °C, resulting in low heat transfer efficiency of the evaporator. Because the vertical ultra-low temperature refrigerator has relatively high humidity, the moisture in the air is easy to frost on the surface of the evaporator, and even freezes, which affects the heat transfer effect of the evaporator. In order to prevent the outer frost layer of the evaporator from being too thick, it needs to be timely Defrost.
There are two convenient defrosting methods: stop defrost, that is, stop the compressor operation, open the vertical ultra-low temperature refrigerator door, let the temperature rise, and then restart the compressor after the frost layer is automatically melted. Another is the cream. After the articles in the vertical ultra-low temperature refrigerator are carried out, the surface of the evaporator tube is directly washed with tap water having a relatively high temperature to dissolve or fall off the frost layer. In addition to the excessive frosting, the heat transfer effect of the evaporator is not good. The appearance of the evaporator is too thick due to temporary uncleaning, and the heat transfer efficiency is also significantly reduced.
Vertical ultra-low temperature refrigerators have poor heat insulation and heat preservation effects, which can also lead to poor heat transfer effect, poor heat insulation and heat preservation effect, and poor heat insulation performance because the thickness of the insulation layer of the pipeline is insufficient. Mainly due to the improper selection of the thickness of the insulation layer when designing the vertical ultra-low temperature refrigerator or the poor quality of the insulation data during construction. In the process of construction, the insulation moisture-proof function of the insulation data may be destroyed, resulting in moisture, deformation and even erosion of the insulation layer. The heat insulation capacity is reduced, and the loss of the anti-cooling capacity of the vertical ultra-low temperature refrigerator is increased, and the decrease is significantly slowed down.

Another important cause of large loss of cooling is the poor sealing performance, and more hot air invades the vertical ultra-low temperature freezer from the leak. Generally, if there is condensation on the seal of the refrigerator door or the seal of the cold storage wall, it means that the seal is not tight. In addition, frequent switching of the vertical ultra-low temperature refrigerator door or more people into the vertical ultra-low temperature refrigerator will also increase the cold storage loss of the warehouse. The vertical ultra-low temperature refrigerator door should be prevented from being opened as much as possible to prevent a large amount of hot air from entering.
These look to help the staff of the vertical ultra-low temperature refrigerators to work with friends, for detailed work conditions and maintenance instructions.
Похожие рекомендации
-
Преимущества оборудования для криогенной обработки подшипников
1138Одним из названий ультранизкотемпературного морозильника является оборудование для криогенной обработки подшипников. Ультра-низкотемпературный морозильник Wuxi Guanya LNEYA разработан для большого соотношения объема; большая емкость конструкции подшипника; может установить температуру...
Посмотреть детали -
Semiconductor refrigeration temperature control table cooler operation instructions
1191The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching bet...
Посмотреть детали -
Precautions for the use of chemical refrigeration and heating circulation systems
1065In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Посмотреть детали -
Water cooled low-temperature circulators in the testing industry of new energy vehicles
1022The development of the new energy vehicle industry is relatively rapid. Driven by technological innovation, it is believed that the new energy vehicle industry is facing opportunities. However, with the development of the new energy vehicle indu...
Посмотреть детали