Precautions for the use of chemical refrigeration and heating circulation systems
In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relatively simple, and the process of reducing the temperature in the reactor to room temperature takes a particularly long time, and the heat energy cannot be used rationally, resulting in a waste of some resources. However, if the waste heat is released too much, the overall temperature will drop unstable, and the product quality will be affected. Therefore, it is very important to have a cooling and heating cycle system.
The characteristic of the reactor is that the volume and heat capacity are very large, and endothermic and exothermic reactions can occur at any time, so the entire process time will be lengthened when collecting. When the polymerization reaction occurs in the reactor, the chemical raw materials are changing, which will cause changes in the process and materials, and a series of endothermic and exothermic reactions occur. Therefore, the chemical production itself is very complicated.
Points for attention in the use of chemical refrigeration and heating cycle systems
(1) When the reactor is in operation, it needs to strictly follow the relevant standards to prevent over-temperature and over-pressure.
(2) Strict temperature control in accordance with requirements.
(3) It is necessary to prevent the superposition of temperature difference stress and internal pressure stress to ensure that the equipment does not appear to be strained.
(4) The ratio of ingredients must be strictly controlled to prevent violent reactions.
With the rapid development of society, in order to adapt to the current development needs of the chemical industry, it is necessary to strengthen temperature control in the chemical production process and optimize the design of the temperature control system to ensure that it meets the requirements for use and ensures the normal operation of the equipment.
Похожие рекомендации
-
How to check the air tightness of 40 screw freezer?
1887Air tightness is related to the cooling effect of the entire 40-screw freezer. Therefore, the manufacturer of 40-pin screw freezer of LushiA (LNEYA) recommends that users do 4 inspections, then how to check the work? This test is carried out on a ...
Посмотреть детали -
Малый компрессор испытательной камеры для окружающей среды должен быть внимательным после обслуживания
1655В центробежной малогабаритной экологической испытательной камере устройство рекуперации всасывания обычно представляет собой независимую систему, и при необходимости трубопровод, соединенный с конденсатором и испарителем, может быть закрыт для отдельного обслуживания. После р...
Посмотреть детали -
Метод отключения в случае отказа высокоточного высокотемпературного циркулятора
1855Высокоточный высокотемпературный циркулятор является одним из видов оборудования, используемого в фармацевтической и химической промышленности для поддержки различных реакторов. Если во время эксплуатации произойдет аварийное отключение электроэнергии, пользователям следует обратить внимание на оперативн...
Посмотреть детали -
Обычно существует три способа контроля температуры в лабораторных реакторах
14911. Manual control: Manually operate the knob on the front of the reactor controller.2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.3. Controlled by thermostat: Silicone oil...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик