Cooling method for laboratory evaporative instruments in operation

Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When purchasing a suitable cooling water circulator, important factors to consider include: 1. Minimum condensing temperature and corresponding cooling capacity; 2. Circulating pressure; 3. Circulating flow rate; 4. Suitable accessories.
When selecting and setting the temperature of the cooling water cycle machine, it is generally recommended to follow the “Rule of 20”, that is, set a temperature difference of 20°C between the heating pot temperature and the steam temperature, and between the steam temperature and the condenser temperature. The lower the temperature that the cooling water circulation machine can provide, the better the condensation effect. The cooling water cycle machine usually has the maximum cooling capacity at 20°C or normal temperature, that is, the maximum cooling power parameter under ideal conditions, which is often the nominal cooling power marked by the manufacturer.
Our LNEYA cooling water circulator will provide cooling capacity of 20°C and 10°C, and different power supply will also be provided for model selection reference. It adopts international brand compressor, user-friendly design, stable performance and continuous work, flexible and convenient operation, multiple fault alarms and start-up delay protection, and the most important thing is that it is guaranteed to run continuously 24 hours a day.
If you also need temperature control of laboratory instruments, you can contact us for solutions. Email: sales@lneya.com
I hope to hear from you soon.


Похожие рекомендации
-
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
1190The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...
Посмотреть детали -
Precautions for the use of chemical refrigeration and heating circulation systems
1080In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Посмотреть детали -
What tests are used by cooling water chillers for new energy enterprises?
953In the process of product development, production and quality control, new energy enterprises will use cooling water chillers to perform a variety of tests. Cooling water chillers play an important role in these tests to ensure the perform...
Посмотреть детали -
Selection of Temperature Control System for Laboratory Resin Reaction Kettle
10741. Choose from the quality of the laboratory resin reactor temperature control system: can affect the quality of the laboratory resin reactor temperature control system, may be the use of accessories. There are some small factories on the market t...
Посмотреть детали