Disadvantages and advantages of general heat transfer oil heating circulation system

The heat conduction oil heating circulation system adopts a fully closed loop structure to directly act on the heat energy to the heated medium. Its advantages are:
(1) Due to the continuous renewal of the heat transfer surface, the heat loss is small;
(2) The temperature field distribution state of the medium can be changed during operation;
(3) Multiple units can be used in parallel. The closed circulation system has a wide range of applications, such as various boilers, industrial furnaces, air preheaters, dryers, ovens and other places that require heat transfer.
But it also has many shortcomings, mainly as follows:
(1) Air resistance is easy to occur when there is gas or liquid in the system;
(2) It is not easy to realize automatic control and remote control;
(3) It is difficult to adapt to high temperature and high pressure occasions.
LNEYA’s heat conduction oil heating circulation system adopts the complete cooling process to achieve 300°C to 50°C cooling, which can continuously increase and decrease the temperature. There is no oil mist volatilization at high temperature, and the heat transfer oil will not be oxidized and browned. It has the function of correcting the internal circulation temperature probe PT100. With safety protection functions, such as self-diagnosis, high-voltage pressure switch, overload relay, thermal protection device, etc. When the system is running, the pressure will not increase due to high temperature, and the heat transfer medium will be automatically replenished at low temperature.
Похожие рекомендации
-
Анализ процесса замены хладагента в промышленном холодильном агрегате
1013Refrigerant is an indispensable part of the refrigeration system of the industrial chiller. During the operation of the industrial refrigeration unit, the refrigerant constantly changes in the industrial refrigeration unit to achieve the cooling e...
Посмотреть детали -
Как выбрать лабораторный охладитель деионизированной воды?
1175Pure water usually refers to water that has been treated to remove impurities, ions, organic matter, etc. Common examples include distilled water, reverse osmosis water, and deionized water. Deionized water has low conductivity due to t...
Посмотреть детали -
Празднуйте Новый год и встречайте Новый год
1318When the bells echo in the clear night sky,When the calendar turns to a new page,We are about to usher in a new year.Thanks for this year's harvestLet us have precious experience on our growthThere is always a reward for sweatThis yearWe sh...
Посмотреть детали -
Шнековый чиллер с шумом должен быть своевременно проверен и отремонтирован
1034Before we use an industrial screw chiller factory, we will check all aspects of it, such as parts inspection, configuration, noise, and so on. What should I do if there is noise in the screw chiller during use? Do I need someone to repair it? The ...
Посмотреть детали