What do the LNEYA chiller fault codes mean? What is the solution?
Q: What is the fault code of the chiller?
Answer: E1 means extremely high indoor temperature alarm, E2 means extremely high temperature alarm, E3 means extremely low temperature alarm, E4 means indoor temperature controller failure, E5 means water temperature sensor failure, E6 means water output alarm, etc. . The fault codes of industrial chillers are in different manufacturers. The fault codes are different. According to the different chiller fault codes, it is easier to find the fault problem and deal with the chiller fault immediately.
Generally, people will see two areas on the control panel of the device, namely the PV area and the SV area. The former one expresses the specific temperature, and the latter one sets the temperature. When a fault occurs, the PV displays the information fault number and the SV displays the information fault name.
For example, the number of the information fault displayed in the PV area is 1, and the name of the information fault displayed in the SV area is Err01. The reason is wrong phase maintenance failure, three-phase power failure (suspicion is caused by wrong phase / reverse phase / phase leakage);
When the number of the information fault displayed in the PV area is expressed as 2, 3, and 4, the name of the information fault displayed in the SV area is also Err02, Err03, and Err04. The reason is the high pressure of No. 2 refrigeration compressor, the bottom pressure of No. 2 refrigeration compressor, and the load of No. 2 refrigeration compressor. At this time, the solution is to stop No. 2 refrigeration compressor;
When the number of information faults displayed in the PV area is expressed as 5, 6, and 7, the names of the information faults displayed in the SV area are also Err05, Err06, and Err07. The reason is the high pressure of No. 2 refrigeration compressor, the bottom pressure of No. 2 refrigeration compressor, and the load of No. 2 refrigeration compressor. At this time, the solution is to stop No. 2 refrigeration compressor;
The number of the information fault displayed in the PV area is 8, and the name of the information fault displayed in the SV area is Err08. The reason is that the refrigerated centrifugal water pump is too low, the solution is that the water flow of the refrigerated pump is not enough (shutdown group);
The number of the information fault displayed in the PV area is 9, and the name of the information fault displayed in the SV area is Err09. The reason is the load of the refrigerated centrifugal water pump, the solution is that the load of the refrigerated pump is large (shutdown group);
The number of the information fault displayed in the PV area is 10, and the name of the information fault displayed in the SV area is Err10. The reason is that the cooling circulation water pressure is too low (the centrifugal fan is over temperature), the cooling pump water flow is not enough (to stop all refrigeration compressors and cooling pumps, the refrigeration pump does not need to stop);
The number of the information fault displayed in the PV area is 11, and the name of the information fault displayed in the SV area is Err11. The reason is that the cooling centrifugal water pump load (centrifugal fan load) and the cooling pump load are very large (to stop all refrigeration compressors and cooling pumps, the refrigeration pump does not need to stop);
The number of the information fault displayed in the PV area is 12, and the name of the information fault displayed in the SV area is Err12. The reason is that the refrigerating temperature is lower than the temperature set by SV (S2), shut down the group. In some cases, other fault codes will continue to appear, and people are not going to analyze it here today.
In the whole process of applying the industrial chiller, many problems are caused by the alarm of the industrial chiller. There are many different methods of alarm, generally light effect alarm, audible alarm and code alarm. According to the different manufacturing design schemes of the chiller plant, the types of alarm methods that will be generated by the same problem are different, but whether it is a light effect alarm or a sound and code alarm, it must be highly valued by the customer. The common alarm problem of industrial chillers is the high pressure and low pressure alarm.
There are many reasons for the bottom pressure alarm, which is caused by the large refrigerant charge or related problems. Most of the high pressure alarms are caused by problems such as overtemperature and insufficient refrigeration, including insufficient refrigerant quantity or cooling water flow (water-cooled heat sink chiller closed cooling tower and its centrifugal water pump, pipeline), refrigerant leakage or pipeline Blockages, debris, and dirt, and the chiller system software cause problems such as low total flow and slow water flow, which eventually cause alarms and failures.
The above is the editor’s introduction to the fault code of the chiller, and related content! I believe that everyone should already know something. Today I will introduce so much to you. If you still do n’t understand anything, I will always answer it for you!
ΠΠΎΡ
ΠΎΠΆΠΈΠ΅ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΈ
-
Advantages of laboratory low-temperature circulators
1301The laboratory low-temperature circulator can simultaneously provide constant temperature and current refrigeration, heating, and temperature control equipment. The laboratory low-temperature circulator has a reasonable structure, simple operati...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
Water cooled low-temperature circulators in the testing industry of new energy vehicles
1585The development of the new energy vehicle industry is relatively rapid. Driven by technological innovation, it is believed that the new energy vehicle industry is facing opportunities. However, with the development of the new energy vehicle indu...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
Precautions for the use of chemical refrigeration and heating circulation systems
1571In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
Precautions for use of minus 95 degrees cryogenic liquid bath cold trap
1716The minus 95 degree low temperature liquid bath cold trap (that is, the refrigerator that we often say) is a common refrigeration unit in refrigeration equipment. The rational use of the unit can not only avoid the failure of the unit, but also ma...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ
LNEYA ΠΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΠ΅ ΡΠΈΠ»Π»Π΅ΡΡ ΠΡΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡΠ΅Π»Ρ ΠΠΎΡΡΠ°Π²ΡΠΈΠΊ