Temperature Forcing System/ Thermal Stream Head AES -115℃~225℃Gas Cooling Chillers Охладители для испытаний полупроводников Time switching10s~20sХладагентR404A/R23/R14/R508BОхлаждающая вода0.6m³/h~3m³/h Диапазон мощности3,7 кВт ~ 7,5 кВтсистема охлаждения при реактивном ударесистема температурного форсированияТермальный поток REQUEST TEMP SHOCK TEST AIRFLOW HOOD 1/CHARACTERISTIC ANALYSIS 2/LOOP TEST 3/IMPACT TEST 4/FAILURE ANALYSIS Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc. Параметры Модель AES-4535 AES-6035 AES-8035 AES-A1035W AES-A1235W AES-4535W AES-6035W AES-8035W Температура. Диапазон -45℃~225℃ -60℃~225℃ -80℃~225℃ -100℃~225℃ -120℃~225℃ Мощность нагрева 3,5 кВт 3,5 кВт 3,5 кВт 4,5 кВт 4,5 кВт Temp. Control Accuracy ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ Temp. Conversion Time -25℃ to 150℃ Approximately 10S150℃ to -25℃Approximately 20s -45℃ to 150℃ Approximately 10S150℃to -45℃Approximately 20s -55℃ to 150℃ Approximately 10S150℃to -55℃Approximately 15s -70℃ to 150℃ Approximately 10S150 ℃to -70℃Approximately 20s -80℃ to 150℃ Approximately 11S150℃to -80℃Approximately 20s Air Requirement Air Cleaner<5um Air Oil Content:<0.1ppm Air Temp&Humidity:5℃~32℃ 0~50%RH Air Handing Capacity 7m3/h ~ 25m3/h Pressure 5bar~7.6bar System Pressure Dispiay Давление в холодильной системе определяется с помощью манометра (высокое давление, низкое давление); Давление в системе кровообращения определяется датчиком давления и отображается на сенсорном экране. Контроллер Siemens PLC, Fuzzy PID Control algorithm. Темп. Контроль Control of outlet temperature Программируемый Можно разработать 5 процедур, и каждая программа может состоять из 40 шагов Протокол общения Ethernet Interface TCP/IP Protocol. Internal Temp. Feedback Equipment outlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (water cooling equipment is configured) . Temp. Feedback T Temperature Sensor Компрессионный двигатель Taikang,France Taikang,France Taikang,France Italy Duling Italy Duling Испаритель Double-pipe (heat) Exchanger Calorifier Flanged Barrel Heater Аксессуары для холодильного оборудования Danfoss / Emerson fittings (dry filters, oil separators, high and low pressure protectors, expansion valves, solenoid valves). Панель управления Цветной сенсорный экран LNEYA с диагональю 7 дюймов, отображение температурных кривых\ экспорт данных EXCEL Безопасная охрана С функцией самодиагностики; выключатель последовательности фаз, защита от перегрузки морозильника; реле высокого напряжения, реле перегрузки, устройство тепловой защиты и другие защитные функции. Криоген Topsubmixed Refrigerant External Insulation Hose 8m DN32 fast coupling clamp for easy outgoing insulation hose Хладагент R404A R404A/R23 R404A/R508B R404A/R23/R14 R404A/R23/R14 Shape Dimension (Wind)cm 54*69*132 54*69*132 75*73*133 80*120*185 100*150*185 Shape Size (Water)cm 54*69*132 54*69*132 75*73*133 70*100*175 80*120*185 Air-Cooled Type Copper tube aluminum fin condensation mode, upper and out type, condensing fan using Germany EBM axial flow fan. Water-Cooled Type W Тип W имеет водяное охлаждение Water-Cooled Condenser Sleeve type heat exchanger (Paris/ Shen’s) Cooling Water Quantity At 25℃ 0.6m3/h 1.2m3/h 1.6m3/h 2.6m3/h 3 м3/ч Источник 380V 50HZ 3.7kW max 5 кВт макс. 5 кВт макс. 6.8kW max 7,5 кВт макс. Источник Настраиваемые 460В 60HZN 220В 60HZ трехфазные Материал корпуса Cold rolled sheet spray (Standard Colour 7035). Temp. Spread High Temperature To +300℃ Descriptions The output airflow cover of the testing machine will be covered bythe test product to form a test chamber with a relatively closedspace. The high or low temp airflow output by the testing machinewill cause the surface temp of the test product to change drastically,thus completing the corresponding high and low temp impact test. It can isolate one lC or original component among many componentsand separately perform high and low tempimpact withoutaffecting other surrounding devices. Compared with the traditionalthermal shock test box, the temp impact rate is faster. Provides accurate and fast ambient temperature (-120 °C ~ +300 °C) for chips, modules, integrated circuit boards, and electronic components. It is an indispensable instrument for product electrical performance testing, failure analysis, and reliability assessment. Widely used in semiconductor companies, aerospace, optical communications, universities, research institutes and other fields. Compared to the traditional thermostat, there are several features: Temperature range: -120 °C ~ +300 °C; The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds; Temperature control accuracy: ±1 °C; Temperature setting capability: ±0.1 °C; Temperature display capability: ±0.1 °C; Maximum air flow: 25m3/h; Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time; The temperature rise and fall time is controllable, programmable operation, manual operation and remote control. REQUEST A QUOTE Send us a message about AES series**正在提交中....提交成功!提交失败!请稍后再试邮箱错误!电话错误! Recommended products FLTZ Double Frequency Conversion Series Product data downloadConfiguration Detailschillers that control the processing temperature on the Fab equipmentsApplicationsrecommend products Model FLTZ-305W FLTZ-305W/2T Double System Temp Range -30℃~40℃ -30℃~40… FLTZ Multi-channel Series Temperature control in semiconductor production testing processesEnsure stable and reliable overall semiconductor process flow from front-end to back-endConfiguration DetailsDescriptionschillers that control the processing temperature on the Fab e… Теплообменный чиллер ETCU Temperature control in semiconductor production and testing processesEnsure stable and reliable overall semiconductor process flow from front-end to back-endConfiguration DetailsProductDescriptionApplication scenarios of temperature control in sem…загрузка...已经是到最后一篇内容了!