The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature chiller system, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
Похожие рекомендации
-
Precautions For Compressor Installation of the Screw Chiller Factory
1129When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate ...
Посмотреть детали -
Solution to the failure of the refrigeration and heating system of the reactor
1018When selecting the pipe material for the reactor refrigeration and heating system, you must pay attention to the connection of the pipe, the choice of the pipe and the material of the pipe. Because the pipe involves cooling and heating, you must r...
Посмотреть детали -
Как заменить четырехходовой клапан машины охлажденной воды?
1117После длительного использования четырехходовой клапан машины для охлажденной воды нуждается в своевременной замене, так как же его заменить? Вы можете ознакомиться с предложениями. При замене машины для охлажденной воды необходимо снять соединительную трубку...
Посмотреть детали -
Disadvantages and advantages of general heat transfer oil heating circulation system
1091The heat conduction oil heating circulation system adopts a fully closed loop structure to directly act on the heat energy to the heated medium. Its advantages are: (1) Due to the continuous renewal of the heat transfer surface, the heat loss is s...
Посмотреть детали