Practical application area of air-cooled chiller
Air cooled chillers, as the name implies,
are mainly used in colleges and universities, scientific research and
laboratories. Specially for the cooling of small laboratory equipment such as
spectrometer, mass spectrometer, viscometer, rotation, fermentation device, a
rotary evaporation apparatus, etc. to make them work under the suitable working
temperature.
In fact, the lab water chillers are also
called air cooled chillers. It can also be used for cooling with small
instruments or small power equipment. For example:
1. Vacuum pump and medical equipment:
molecular pump, diffusion pump, cooling blanket, X-ray machine, nuclear
magnetic resonance, accelerator;
2. Industrial equipment and other: laser
equipment, vacuum coating equipment, biological pharmacy, mold, machine tool,
vacuum furnace, welding machine, reaction kettle.
3. Matched small vacuum pumps, such as
molecular pumps, oil and gas recovery pumps, small roots pumps, rotary disc
pumps, slide valve pumps, etc. It has the advantages of convenient connection,
simple operation, stable temperature, and saving water and electricity,
providing a stable temperature environment for the vacuum equipment, and
providing the operating efficiency of the equipment.
Air cooled chillers belong to LNEYA refrigeration
heating system temperature control equipment.
Advantages and functions of temperature
control system of refrigeration:Temperature range from 120℃ до 350℃,
performance superior, unique, high – precision, intelligent temperature
control.High cooling power from 0.5 to 1200kW, highest production stability and
repeatable results.Multi-function alarm system and safety function, use plate
heat exchanger, tube type heater to increase heating and cooling rate.
No heat conduction medium evaporates at high
temperature, and it can be achieved -80℃~190℃, -70℃~220℃, -88℃~170℃, -55℃~ 250℃, -30℃~ 300℃ continuous
temperature control without pressurization.The principle and the function has
many advantages to using staff: because only expansion of cavity in the body
heat conduction medium contact with oxygen in the air (and expansion tank
temperature at room temperature to 60℃), can achieve lower
heat conduction medium absorbed by oxidation and the risk of air moisture.
Похожие рекомендации
-
Why do chemical raw materials require low-temperature chillers?
897The main reasons for using low-temperature chillers in the production process of chemical raw materials are as follows: Temperature control: Many chemical reactions are temperature sensitive and require precise temperature control to...
Посмотреть детали -
Использование и обслуживание системы контроля температуры в лаборатории/биоинженерии
9591. Перед использованием внимательно прочитайте руководство по эксплуатации оборудования, ознакомьтесь с процессом работы и основными инструкциями и работайте в строгом соответствии с условиями, указанными в руководстве. 2. При перемещении лабораторного/биоинженерного темпер...
Посмотреть детали -
Форма конфигурации циркуляционной отопительной установки для лаборатории
943The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
Посмотреть детали -
Closed laboratory circulator enameled mixing tanks refrigeration and heating system
879Closed laboratory enameled mixing tanks refrigeration and heating system
Посмотреть детали