Использование и обслуживание системы контроля температуры в лаборатории/биоинженерии
1. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual.
2. When moving the laboratory/bioengineering temperature control system, avoid striking the equipment shell, vibrating and damaging or polluting the keypad (function key display).
3. Before use, make sure to regularly check (at least once every two years) whether the equipment is in normal working condition.
4. The laboratory/bioengineering temperature control system shall be stored or used in a clean environment with sufficient fresh air to prevent pollution. There is more than 30cm space around, and the ground is flat and firm. Ensure that the input power is properly grounded when using.
5. Before any repair, maintenance or moving the equipment, the equipment must be turned off and the power supply must be disconnected. The tilt angle of the laboratory/bioengineering temperature control system should not exceed 15 degrees when moving. When the laboratory/bioengineering temperature control system needs to move for a long distance, it is necessary to empty the liquid in the equipment and carefully check the pipe connections to ensure that there is no leakage.
6. When selecting the heat conduction medium, pay attention to whether its upper and lower temperature limits, ignition point, viscosity, freezing point, etc. meet the requirements, and whether it is suitable for the use of the internal pipes of the instrument. Use the heat conduction medium specified by the manufacturer and within the specified pressure range.
7. When selecting the heat transfer medium pipe, the length should be as short as possible and the diameter should be as large as possible. If the diameter is too small, it may cause flow restriction. Do not knot the heat transfer medium pipeline of the high and low temperature all-in-one machine, and check it regularly to avoid material strain (such as fission).
8. Regularly check the liquid sight glass on the side of the equipment to confirm whether the liquid level of the heat transfer medium is at the normal position. Regularly replace the thermal conductivity medium of the laboratory/bioengineering temperature control system. If water is mixed with immiscible oil and water, the mixed liquid will expand after heating, and will spray under high temperature, even causing personal injury.
9. The equipment adjustment parameters must be reset after the new heat conduction medium is filled.
The above are technical maintenance and use matters. If you have other information needs about the equipment, you can leave a message to us, or even send an email to sales@lneya.com
Похожие рекомендации
-
Как избежать неправильной работы циркуляционного насоса отопления и охлаждения?
1631When the user runs the heating and cooling circulator, the operation needs to follow the instructions. Then, how to avoid unsuitable operation? LNEYA heating and cooling circulator has multi-function alarm system and safety function. It uses plate...
Посмотреть детали -
Как устранить сигнал тревоги высокого давления в промышленном ультранизкотемпературном морозильнике?
1416В процессе эксплуатации, если неисправность не будет устранена вовремя, это повлияет на использование промышленного ультранизкотемпературного морозильника. Как решить проблему сигнализации высокого давления? Если промышленный ультранизкотемпературный морозильник с водяным охлаждением подает сигнал о высоком давлении...
Посмотреть детали -
Какие места стоит выбрать для охлаждения?
1907Сегодня, с развитием науки и техники, многие покупатели ориентируются на использование высоких и низких температур для улучшения качества продукции и снижения ее стоимости. Так на что же следует обратить внимание при выборе модели? Человек...
Посмотреть детали -
Laboratory Polymerization Reactor Water Cooling Chiller
1259Laboratory Polymerization Reactor Water Cooling Chiller is a device used to accurately control the temperature inside the reactor, especially for polymerization reactions that need to be carried out under specific temperature condition...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик