What is the reason why the industrial chiller system cannot be cooled
Let the LNEYA technical engineer explain
the reason for everyone:
The first one: The chiller system fails to
lower the temperature during the first use, or there is a problem with the
installation of the industrial water chiller, cooling tower, circulating water
pump and piping. Need to check carefully according to the installation drawing.
The second one: It may be because the
pipeline is connected to various equipment for a long time, and impurities
accumulate in the water source, which causes the water flow to become smaller.
Therefore, we must clean the pipes between the equipment.
Third: If this problem occurs during the
first use, it may be caused by a mismatch of the chiller and a shipping
problem. Because the industrial water chiller has undergone 100% performance
testing before leaving the factory to ensure the normal operation of the unit.
Finally, if it is a chiller that has been
used for half a year or 1-2 years, it may be caused by a leak of Freon in the
cooling system of the chiller. It is recommended to find out the leaks,
re-soldering, and re-soldering the refrigerant. The heat exchanger of the
industrial water chiller is dirty and needs to be cleaned. Remember to clean it
regularly in the future.
The operation of any industrial water chiller
system is inseparable from the participation of refrigerants. Therefore, the
shortage of refrigerant will also affect the normal operation of industrial
chillers, leading to reduced cooling capacity or even shutdown
of industrial water chillers. This is also the main reason for the shrinking
capacity of industrial chillers.
Похожие рекомендации
-
The difference between direct contact liquid cooling and cold plate liquid cooling technology
2012The cold plate liquid cooling technology is an implementation method in which the heat of the heating components is indirectly transferred to the cooling liquid enclosed in the circulating pipeline through the cold plate, and the heat is...
Посмотреть детали -
What should I pay attention to when using the reactor for chilling and cooling?
1716When using the reactor chilling and cooling and cooling device, users need to pay attention to their refrigeration and heating operations. Pay attention to the operation within a reasonable temperature range to avoid excessive temperature and pres...
Посмотреть детали -
What are the factors related to the selection of heating and refrigeration circulators?
1667Heating and refrigeration circulators are used in many laboratory projects. They are usually equipped with reactors and reactors for cooling, heating and temperature control. Then, what factors are related to the selection of heating and cooling i...
Посмотреть детали -
Heating and cooling system for chemical reaction kettle reaction process
1827In the process of chemical chemical reaction, material temperature is an important production process parameter. For example, in salt crystallization, solution separation, organic pigment and intermediate processing, temperature control is particu...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик