Как установить -60°C криогенный охладитель производители оборудования
-60℃ cryogenic chiller
manufacturers are used in the refrigeration and chemical industry, so what
issues should be paid attention to during installation? LNEYA professional
manufacturers tell you that you should install according to the instruction
manual.
For the -60℃cryogenic chiller
compressor (unit) that has been tested at the factory and is protected by
rust-proof seals and has good pre-installation protection measures, it can be
directly installed, the protection measures are invalid, or the compressor (unit)
has obvious defects. Check it and install it after confirming that it meets the
factory manufacturer’s factory standards.
-60℃ cryogenic chiller
compressor (unit) should check the position of the foundation and anchor bolt
holes before it is in place, it should meet the requirements of the design
documents; it should be installed in the foundation and bracket according to
the connection method required by the design and equipment technical documents.
Welding shall not be used on hangers and on the design and equipment technical
documentation. The installation should meet the requirements of the equipment
technical documents. When leveling is required, the horn should be used. The
installation should keep the body stable and should not exceed the inclination
angle of the technical documentation of the equipment. Do not invert.
-60℃ cryogenic chiller
compressor (unit) manufacturer to ensure that the compressor does not corrode
after leaving the factory and before use, no impurities, more inert gas for sealing
treatment, so as long as the seal is intact, no obvious defects can be directly
installation. For small, lightweight-50-degree cryogenic unit compressors
(units), manual handling can be carried out during the installation process.
Due to exceeding the limit angle or inversion, internal
irreparable damage may occur, so standard handling is required. Refrigeration
auxiliary equipment such as intercooler, gas-liquid separator, oil separator,
liquid receiver, low-pressure circulating reservoir, oil collector, chiller,
condenser, etc. in the refrigeration system shall be installed in accordance
with current standards.
-60℃ cryogenic chiller
manufacturers Wuxi Guanya (LNEYA) will be arranged at the factory, the
corresponding instructions to follow the equipment, the user can install
according to the instructions.
Похожие рекомендации
-
What is a laboratory glycol chiller What should I pay attention to
1217The laboratory glycol chiller is a commoncooling equipment in the laboratory. It is generally used to achieve thetemperature requirement of the cold source. What are the benefits?1. Why choose a laboratory glycol chiller:The single-machine self-...
Посмотреть детали -
What are the conditions for the decarboxylation reaction? How to control the temperature of heating?
1218The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group i...
Посмотреть детали -
The principle of LNEYA chiller
1137Industrial chillers are commonly used to cool products and machinery for a variety of different applications, including injection molding, tools and die cutting, food and beverage, chemicals, lasers, machine tools, semiconductors and more. In most...
Посмотреть детали -
Циркулятор нагрева реактора Связанные инструкции
1077В настоящее время циркуляционные насосы для обогрева реакторов чаще всего используются в химической промышленности. На что же нужно обратить внимание пользователям после покупки? С развитием общества технологический уровень реакторных нагревательных циркуляторов становится все более и более...
Посмотреть детали