AET -75℃~250℃
Air Cooling Chiller For chuck/chamber/Heat plate- Точность контроля температуры±0.5℃
- Air treatment22m³/h~95m³/h
- Тип охлажденияwater cooling/air cooling
Suitable for IC testing of all kinds of semiconductor chips,flash memory Flash/EMMC, PCB circuit boards, opticalcommunications,electronic industries, etc.
Модель | AET-4025 | AET-4050 | AET-4095W | AET-7025 | AET-7050W | AET-7095W |
AET-4025C | AET-4050C | AET-4095WC | AET-7025C | AET-7050WC | AET-7095WC | |
Диапазон температур | -40℃~250℃ | -75℃~250℃ | ||||
Точность контроля температуры | Gas outlet temperature control ±0.1°C, long-distance process temperature control accuracy ±0.5°C. You can choose to control the outlet gas temperature and process target temperature | |||||
Upgrade temperature rate | The temperature rise and fall rate of the gas temperature at the equipment outlet is greater than 30°C/min, and gradient temperature rise and fall can be performed | |||||
Air requirements | Air filter <5um Air oil content <0.1um Air temperature and humidity: 5°C-32℃℃ 0-50%RH Pressure 4bar~8bar | |||||
Air treatment | 22m³/h | 50 м³/ч | 95m³/h | 22m³/h | 50 м³/ч | 95m³/h |
Метод дросселирования | The refrigeration system uses electronic expansion valve throttling to accurately control the cooling capacity | |||||
Контроллер | PLC programmable controller, standard support Modbus RTU protocol, RS485 interface, other communication protocols can be selected | |||||
Display record | 7-inch color touch screen, can display gas temperature, pressure, flow, refrigeration system pressure and temperature | |||||
Контроль температуры процесса | Self-created model-free self-building tree algorithm combined with general anti-lag cascade algorithm to control process temperature | |||||
Размеры см | 43*46*112 | 52*57*132 | 60*63*160 | 54*69*112 | 65*85*132 | 75*95*160 |
Remarks | Suffix W represents water cooling and suffix c represents gas recycling |
Descriptions
Номинальные условия испытаний: температура сухого термометра 20℃; температура влажного термометра 16℃. Температура воды на входе 20℃; температура воды на выходе 25℃.
The data in this table is for reference only. Please refer to the unit nameplate parameters.
If you need special non-standard customization, please contact our company
ЗАПРОСИТЬ ЦЕНУ
Рекомендуемые продукты
Серия FLTZ с двойным преобразованием частоты
Модель FLTZ-305W FLTZ-305W/2T Двойная система Диапазон температур -30℃~40℃ -30℃~40℃ -30℃~40℃ Точность регулирования температуры ±0.1℃ ±0.1℃ ±0.1℃ Управление потоком 15~45L/min ±0.3 15~45L/min ±0.3 15~45L/min ±0.3 Давление насоса 6 бар м...
Многоканальная серия FLTZ
Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates continuously for 24 hours Mainly used for precise temperature control in semiconductor prod…
Теплообменный чиллер ETCU
Temp Range:+5℃~90℃ ±0.3℃ Cooling Capacity: 5kw~30kw Tank volume: 6L~15L Power: 06KW~1.6KW Heating method within 40 ℃ adopts a compressor hot gas heating fully enclosed design, and the machine operates…
загрузка...