Шнековый чиллер с шумом должен быть своевременно проверен и отремонтирован
Before we use an industrial screw chiller factory, we will check all aspects of it, such as parts inspection, configuration, noise, and so on. What should I do if there is noise in the screw chiller during use? Do I need someone to repair it?
The noise of the screw chiller factory is mostly caused by the friction and the position in the parts such as the compressor and the recirculating pump. When the noise continues to make a sound, it is necessary to carry out a comprehensive inspection of the accessories and deal with the problem parts of the noise effectively. If the noise is caused by the water pump of the screw chiller, it means that the water quality or the pump is abnormal. It is necessary for the enterprise to check the utilization conditions of the screw chiller in time, and equip the water tower with water quality. Only ensuring the water quality meeting with the lowest of the industrial refrigerator is it possible, maybe, to protect the safe operation of the pump, thereby preventing the pump from being overloaded and causing an irritating noise. The steps to check the noise are extremely simple. If you can’t do that, you can ask a professional manufacturer to check the repair. If the screw chiller factory is caused by a problem that belongs to the inner fitting, try repairing the fitting or changing the new fitting. This is an effective way to solve the noise.
Screw chiller factory is a common chiller in the industry. Whenever problem occurs, it should be discovered and solved in time. This can protect the screw chiller factory. Have you learned how to check the chiller noise?
Похожие рекомендации
-
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
1172The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...
Посмотреть детали -
Solution to the failure of the refrigeration and heating system of the reactor
1014When selecting the pipe material for the reactor refrigeration and heating system, you must pay attention to the connection of the pipe, the choice of the pipe and the material of the pipe. Because the pipe involves cooling and heating, you must r...
Посмотреть детали -
How to Deal with Fault of Conpressor after Cold Plate Freezer for Sale?
927In the operation of the cryogenic refrigerator refrigeration system, once the compressor fault occurs, it will affect the operation of the cryogenic refrigerator. So what are the faults that affect the compressor? How do clients settle it if the c...
Посмотреть детали -
Этапы работы промышленного чиллера в аммиачной холодильной системе
1066Резиновый шланг, используемый для соединения выпускного клапана, одним концом вставляется в воду в емкости для воды. Когда аммиак в смешанном газе охлаждается до состояния аммиачной жидкости, дно воздушного сепаратора замерзает. В это время ...
Посмотреть детали