100p Freezer Instructions of LNEYA
When the user buys and uses 100 freezers, LNEYA will have relevant instructions for use and will be sent to the user along with the device. So, what should I pay attention to when using the 100p freezer?
When receiving the equipment, the user should first check the outer packaging to see if the accessories are complete. After unpacking, lift the 100p freezer off the wooden packaging base and lay it flat in a spacious position to check whether there is any damage in the transportation. After confirming the error, push it to the installation position, put the 100p freezer in a stable state, and then connect the external circulation and return water pipeline of the device.
It is recommended to clean the water tank and the site before starting. There should be no corrosive gas and harmful impurities in the air. There is no strong electromagnetic field interference around. Avoid direct sunlight on the instrument. Check whether the ferrule or flange bolt of the external hose is Tighten.
100p freezer power supply requirements, need to pay attention to single-phase three-wire system or three-phase five-wire system (corresponding model selection power supply specifications) with good grounding, grounding resistance is not more than 0.1 ohms. Just use the coolant to be injected, and the amount of coolant to be injected is better than the upper edge. To prevent foreign matter from clogging the pipeline, scaling, etc., use deionized water or special coolant. The water tank should be cleaned regularly, and the coolant in the water tank should be replaced regularly to prevent microbial growth.
In addition, the use of the freezer also needs to pay attention to the use of temperature, ambient temperature, temperature control accuracy and flow rate related values, different types of power supply requirements, please correspond to the model.
The instruction manual for the 100p freezer is as shown above. It is better to run the equipment according to the instructions.
Похожие рекомендации
-
The cooling circulation system is used to collect the non-condensable tail gas in the distillation s
1596Most rectification towers are two-stage condensation. The first stage uses cooling water, mainly condensing the top steam, and the second stage uses chilled water or ethylene glycol, which is mainly used to treat tail gas and remove a small amount...
Посмотреть детали -
Почему в циркуляторе низкотемпературного охладителя возникает явление инея?
1686Многие низкотемпературные охладители-циркуляторы замерзают при использовании, но в низкотемпературных охладителях-циркуляторах такого явления не наблюдается. Так в чем же дело? Связано ли это с охлаждением? Прежде всего, почему низкотемпературный охладитель...
Посмотреть детали -
-
На что влияют уровень и разница масла в низкотемпературных охладителях?
1870LNEYA tells you that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil storage and special oil cooler. Oil level It refers to the level of the lubricant in the oil storage container. Th...