Новости

General high and low temperature integrated machine valve repair detailed description
The conventional high and low temperature integrated machine valve replaces the packing, and the main function of the packing is to prevent the working medium from leaking along the axial direction of the valve stem. In case of minor leakage, the packing gland can be tightened. If the leak cannot be eliminated, the packing should be replaced. When replacing, the valve stem must be screwed out to the end. Use the filler needle to pull out the old packing, then screw the prepared new packing in...
Посмотреть детали
Description of refrigeration principle in semiconductor wafer temperature control
In the operation of the semiconductor wafer temperature control refrigeration system, a state transition of a certain working fluid is used, and the necessary heat Q0 is extracted from the heat source of a lower temperature, and the heat Qk is sent to the heat source of the tropical heat through a storage process of the consumption power W. In this process, Qk = Q0 + W is taken from the conservation of energy. In order to achieve temperature control of semiconductor wafer temperature migratio...
Посмотреть деталиCold and hot shock constant temperature and humidity test chamber operation steps
When selecting the appropriate model of the LNEYA hot and cold shock constant temperature and humidity test chamber, you need to pay attention to the operation and installation steps. The user needs to be well prepared for the installation work. The hot and cold shock constant temperature and humidity test chamber should be noted before use. The power supply voltage should be turned on. After the fan is started, open the door and select the required impact height. Then close the door and pres...
Посмотреть детали
Hybrid car battery test equipment cooling capacity description
Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehicle battery test equipment, once the outer surface of the insulation layer is found to have wet or frosted parts, it means that the thickness of the insulation material is insufficient or has been damp, and the insulation material should be added or r...
Посмотреть детали
Protection device details of circulating fluid temperature control device
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time...
Посмотреть детали
LNEYA high and low temperature heating refrigerator maintenance instructions
High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high and low temperature heating refrigerator is used for more than 150 degrees for a long time, check the heat transfer oil every three to six months, and decide whether to replace it according to the actual situation. When replacing the circulating oil, d...
Посмотреть детали
Why is there air in the reactor temperature control system?
The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the power consumption, reducing the cooling efficiency, and possibly the exhaust gas temperature is too high. The carbonization of the lubricating oil affects the lubrication effect, and in severe cases, the refrigeration compressor motor is burnt. The gas g...
Посмотреть деталиExplosion-proof hot and cold machine winter maintenance instructions
When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it in a dry place to prevent freezing and expansion. Damage to machine parts (such as coolers, pumps, connecting copper pipes). The method of removing residual water is as follows: 1. The water sequence series needs to disconnect the cooling water and ...
Посмотреть детали
Стоит ли выбирать центробежный или объемный насос в фармацевтической лаборатории?
Для того чтобы выбрать тип насоса, подходящий для фармацевтической лаборатории, необходимо глубоко разобраться в его характеристиках и понять разницу в конкретном принципе работы. Для этого мы должны понимать, что центробежный насос зависит от давления (или явления переменного потока), в то время как объемный насос имеет более или менее постоянное явление потока, не зависящее от давления.
Посмотреть детали
How to clean the battery cooling system of new energy vehicles?
The battery cooling system of the new energy model first unscrews the three screws on the upper part of the wet curtain, holds the louvers on the upper part of the wet curtain, gently pulls the wet curtain outward and then lifts it up slightly to remove the wet curtain. Then remove the top cover and the water distribution pipe assembly, unscrew the screw on the top cover, lift the top cover up, remove the hose clamp on the water pipe cooling fan and loosen the water supply pipe. The assembly ...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик