Поиск по всей станции


Новости

How to Carry On Industrial Low Temperature Chil...

How to Carry On Industrial Low Temperature Chillerstest Of Choosing The Better Company?

2024-03-19

No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers. Which company's low - temperature chiller is better? Let me tell you, in order to help you to use the industrial low temperature chillers, you have to know these related knowledge of test.When the industrial low temperature chiller is being used, the thermometer of the inlet and outlet of the system is checked through the control system of the unit half an hou...

Посмотреть детали
Батарея модуль тест оборудования выбор ошибки д...

Выбор оборудования для тестирования батарейного модуля Описание ошибок

2024-03-19

Many battery module companies have certain misunderstandings about LNEYA's battery module test equipment. There are some errors in selecting the battery module test equipment model, so try to select the battery module test equipment. Avoid some misunderstandings. Many units thought that as long as the tester can distinguish between PASS and FAIL, they can be tested. It is as simple as using the "PASS machine" of GOINOGO to test the component test system. It should be said that having a test s...

Посмотреть детали
Chip temperature control device selection instr...

Chip temperature control device selection instructions

2024-03-19

With economic development and technological advancement, chip temperature control equipment has been developed by the chip industry. LNEYA, as a chip temperature control equipment manufacturer, also guarantees one of the performance and quality aspects of the chip industry. The electronic appliance control system is the nerve center of the chip temperature control device. It senses the state of the machine by the sensor, accepts manual commands, realizes information exchange with the test sys...

Посмотреть детали
How to test the components of the chip temperat...

Как проверить компоненты температурного контроля микросхемы с помощью мультиметра?

2024-03-19

The chip temperature control device is used in components such as chips, semiconductors, and integrated circuits. How do you use a multimeter for these common components? Transformers, deflection coils, compensation inductors, etc. of electronic components, because the resistance values of the inductive components wound by the wires are very low, the short-circuit faults of them are difficult to measure; the open-circuit faults depend on testing the resistance of the two ends of the component...

Посмотреть детали
What Will Happen to the Over-Cooling of the Low...

Что произойдет с переохлаждением низкотемпературного холодильника?

2024-03-19

As we all know, the low temperature chiller is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the lowest temperature of the low temperature chiller can only reach - 40 degrees. The main reason is limited by the limit operating conditions of single-stage piston compressor. If the evaporator temperature of the chiller is too low, the following probl...

Посмотреть детали
How Does the Low Temperature Chiller Apply to M...

Как низкотемпературный охладитель применяется в литейной промышленности?

2024-03-19

As you all know, the low temperature chiller is widely used, especially in the mould line. So does everyone know how it works in the mould industry? If you don't know, let's have a look with me.When using the low temperature chiller to cool the mould, it usually cools the mould together with the injection machine. Generally speaking, the mould is quite a heat exchanger. Heat is transferred from melting to the mould, and then from the mould to the cooling medium for cooling. As we all know, mo...

Посмотреть детали
How to Solve the Problem of Compressor Noise in...

Как решить проблему шума компрессора в промышленном низкотемпературном холодильнике?

2024-03-19

In industrial low temperature chiller, compressor operation will produce noise, but only thedifference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?Generally speaking, compressor noise must first understand the causes of its noise, in order to better deal with. The main reasons are: the compressor is not fixed well; compressor quality problems; compressor load is too large; compressor power supply is...

Посмотреть детали
Refrigeration Explanation for Screw Compressor ...

Объяснение охлаждения для винтового компрессора низкотемпературного охладителя-циркулятора

2024-03-19

Because of the different compressors, the performance of the low temperature chiller circulators is also different. Screw compressors are different from piston compressors, and the structure is more precise. Therefore, if users need to choose the low temperature chiller circulators, they need to have their own understanding of their refrigeration operation.The screw compressor of the low temperature chiller circulator sprays lubricating oil into the working chamber when it works, which plays ...

Посмотреть детали
Prospects for the development of electronic tes...

Перспективы развития электронных тестовых тепловых систем

2024-03-19

For the modern society, energy conservation and emission reduction is also an important task. In the development of semiconductor, chip, integrated circuit and other industries, the electronic test thermal system can effectively test its temperature range to ensure that such components can Effectively get test results to avoid energy waste and increase costs. The electronic test thermal system has a cooling function when passing through direct current. Since the semiconductor material has con...

Посмотреть детали
Matters Needing Attention in Replacing Refriger...

Вопросы, требующие внимания при замене масла хладагента на заводе по производству винтовых чиллеров

2024-03-19

The refrigerant oil in the screw chiller factory needs regular inspection and replacement. We all know that different grades of refrigerant oil cannot be mixed together, otherwise it will cause abnormal or strike conditions of the screw chiller factory. So, what else should we pay attention to when replacing refrigerant oil? 1. Different grades of refrigerant oil cannot be mixed; especially mineral oil and synthetic ester oil cannot be mixed. 2. If different grades of refrigerant oil need to ...

Посмотреть детали

Новости индустрии

Расширяйтесь!