Новости

Chip temperature control device selection instructions
With economic development and technological advancement, chip temperature control equipment has been developed by the chip industry. LNEYA, as a chip temperature control equipment manufacturer, also guarantees one of the performance and quality aspects of the chip industry. The electronic appliance control system is the nerve center of the chip temperature control device. It senses the state of the machine by the sensor, accepts manual commands, realizes information exchange with the test sys...
Посмотреть детали
Как проверить компоненты температурного контроля микросхемы с помощью мультиметра?
The chip temperature control device is used in components such as chips, semiconductors, and integrated circuits. How do you use a multimeter for these common components? Transformers, deflection coils, compensation inductors, etc. of electronic components, because the resistance values of the inductive components wound by the wires are very low, the short-circuit faults of them are difficult to measure; the open-circuit faults depend on testing the resistance of the two ends of the component...
Посмотреть деталиЧто произойдет с переохлаждением низкотемпературного холодильника?
As we all know, the low temperature chiller is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the lowest temperature of the low temperature chiller can only reach - 40 degrees. The main reason is limited by the limit operating conditions of single-stage piston compressor. If the evaporator temperature of the chiller is too low, the following probl...
Посмотреть деталиКак низкотемпературный охладитель применяется в литейной промышленности?
As you all know, the low temperature chiller is widely used, especially in the mould line. So does everyone know how it works in the mould industry? If you don't know, let's have a look with me.When using the low temperature chiller to cool the mould, it usually cools the mould together with the injection machine. Generally speaking, the mould is quite a heat exchanger. Heat is transferred from melting to the mould, and then from the mould to the cooling medium for cooling. As we all know, mo...
Посмотреть деталиКак решить проблему шума компрессора в промышленном низкотемпературном холодильнике?
In industrial low temperature chiller, compressor operation will produce noise, but only thedifference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?Generally speaking, compressor noise must first understand the causes of its noise, in order to better deal with. The main reasons are: the compressor is not fixed well; compressor quality problems; compressor load is too large; compressor power supply is...
Посмотреть деталиОбъяснение охлаждения для винтового компрессора низкотемпературного охладителя-циркулятора
Because of the different compressors, the performance of the low temperature chiller circulators is also different. Screw compressors are different from piston compressors, and the structure is more precise. Therefore, if users need to choose the low temperature chiller circulators, they need to have their own understanding of their refrigeration operation.The screw compressor of the low temperature chiller circulator sprays lubricating oil into the working chamber when it works, which plays ...
Посмотреть детали
Перспективы развития электронных тестовых тепловых систем
For the modern society, energy conservation and emission reduction is also an important task. In the development of semiconductor, chip, integrated circuit and other industries, the electronic test thermal system can effectively test its temperature range to ensure that such components can Effectively get test results to avoid energy waste and increase costs. The electronic test thermal system has a cooling function when passing through direct current. Since the semiconductor material has con...
Посмотреть детали
Интеллектуальное управление и выбор термостата на чипе
With the continuous development of the chip, its detection is also an important task, because the chip price is relatively expensive, so LNEYA chip intelligent thermostat came into being, professionally solve its chip test problems. The value of the chip is expensive, and the system detection process has deviations in the detection results due to environmental and equipment stability. Therefore, the chip problems with such quality problems are often further tested, resulting in product qualit...
Посмотреть детали
Описание диапазона применения системы температурных испытаний полупроводников
The semiconductor temperature test system is LNEYA's new device for semiconductor chip testing. So what range does the semiconductor temperature test system apply? Users need to understand the specific application range to select the appropriate semiconductor temperature test system. Under normal circumstances, semiconductors, integrated circuits, and chips can be equated because they are actually the same thing. Semiconductors are a kind of material. Because of the high proportion of integra...
Посмотреть деталиPrecautions For Compressor Installation of the Screw Chiller Factory
When the operating conditions of the screw chiller factory restrict the compressor to be installed in a small enclosed space, its ventilation environment should be considered. It is necessary to add ventilation and exhaust equipment to facilitate circulation of air. The capacity of the ventilation and exhaust equipment must be greater than the exhaust volume of the compressor cooling fan, and the exhaust inlet position should be suitable for the hot exhaust outlet position of the compressor. ...
Посмотреть детали