How to Carry On Industrial Low Temperature Chillerstest Of Choosing The Better Company?
No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers.
Which company’s low – temperature chiller is better? Let me tell you, in order to help you to use the industrial low temperature chillers, you have to know these related knowledge of test.
Temperature detection of inlet and outlet
When the industrial low temperature chiller is being used, the thermometer of the inlet and outlet of the system is checked through the control system of the unit half an hour after starting up, which can read the inlet temperature and outlet temperature of the industrial low-temperature chiller. Ensure that the temperature difference between inlet and outlet water is not too large, once it is too large, the water flow may be shown to be small, which may cause the normal operation of the industrial low-temperature chiller.
Water pressure detection of inlet and outlet pipes
It is necessary to test the outlet and inlet water pressure values of industrial low-temperature chillers, and then check the instructions to see how much water flow is under normal conditions to judge whether the refrigeration system is normal. Which company’s low – temperature chiller is better? Let me tell you. We can judge which section of the pipe resistance value is larger, and make the corresponding rectification plan from the line.
Detection of suction temperature of copper tube of compressor
When using industrial low – temperature chillers, after running for half an hour, If the suction temperature of the compressor is detected below 0 degrees, it indicates that the water flow in the heat exchanger does not reach a fixed value. It is easy to cause the drop of evaporation force, which may lead to the refrigerant still absorbing heat in the process of evaporator flowing to the compressor, resulting in the suction temperature of the compressor being lower than 0 degrees.
Current detection during pump operation
During operation, the industrial low – temperature chiller can compare the current in the water pump with the rated current of the chiller. In this way, it can judge whether the current is large or small and detect the operation status of the water system at any time.
These are the methods of testing which company’s industrial low -temperature chiller is better. I hope you can quickly find problems in the chiller when you check it.
Похожие рекомендации
-
Холодильник для охлаждения вакуумной камеры
971Vacuum chamber cooling chiller is a device specially designed to cool the environment in a vacuum chamber to ensure that the temperature in the vacuum chamber is kept within the required working range to meet the needs of specific applicatio...
Посмотреть детали -
Чип ИС выделенный холодильный нагрев тест машины инструкции
1074Полупроводниковый чип Chiller - это симулятор температурных испытаний, используемый в тестировании полупроводников. Как профессиональный производитель, LNEYA имеет широкую температурную ориентацию и высокую температуру подъема и спада, а диапазон температур составляет -92 ° C ~ 250 ...
Посмотреть детали -
The Effect of Heating Cooling Translator
943The whole liquid circulation of the heating and cooling circulator is closed with the expansion vessel. The expansion vessel and the liquid circulation are adiabatic and do not participate in the liquid circulation. This is just a mechanical conne...
Посмотреть детали -
Price Analysis of High Low Temperature Test Chambers
1066As the saying goes, “ You get what you've paid. ” The price of the high low temperature test chamber is related to the quality of its configuration. The technology of Wuxi LNEYA itself is priceless. In the test chamber industry, the high low tempe...
Посмотреть детали