СУНДИ -10℃~150℃
  • Мощность охлаждения0.5kW~10kW
  • Мощность нагрева0.5kW~10kW
  • ХладагентR134A/R1234yf
  • Вес115KG~300KG

Air-cooling & Water-cooling

Детали конфигурации

Модель KRYZ-475
KRYZ-475W
KRYZ-4A15W KRYZ-4A25W
Диапазон температур -40℃~+100℃
Точность контроля температуры ±0.1℃ ±0.1℃ ±0.1℃
Обратная связь по температуре Pt100 Pt100 Pt100
Отображение температуры 0.01k 0.01k 0.01k
Flow output 1~25 L/min 1~25 L/min 1~25 L/min
About traffic description When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value.
Flow control accuracy ±0.1 L/min ±0.1 L/min ±0.1 L/min
Pressure display Using pressure sensor, the pressure is displayed on the touch screen, and the pressure control can be adjusted from 0.2bar to 2.5bar
Heating capacity kW 7.5 15 25
Cooling capacity kW 100℃ 7.5 15 25
  20℃ 7.5 15 25
  0℃ 7.5 15 25
  -20℃ 4.5 10 16
  -35℃ 1.8 4 6.5
Компрессор Inverter scroll compressor
Метод дросселирования Электронный расширительный клапан
Маслоотделитель Эмерсон
Фильтр-осушитель Danfoss
Испаритель Пластинчатый теплообменник
Циркуляционный насос Variable frequency magnetic drive pump
Вход, дисплей 7-inch color touch screen, PLC controller
Programming 5 programs can be compiled, each program can compile 40 steps
Communications Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol
Защита безопасности It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions.
System The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures.
Хладагент R404A/ R507C
Размер интерфейса G3/4 G3/4 G3/4
Water cooled @25℃ 2500L/H
ZG3/4
4000 Л/ЧАС
ZG1
6000 Л/ЧАС
DN32
Конденсатор с водяным охлаждением The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter
Air cooled condenser Microchannel Heat Exchanger / /
Power supply 380V50HZ 14 кВт 25 кВт 38 кВт
Размеры см 55*85*175 70*100*175 80*120*185
Вес 280 кг 360 кг 620kg
Standard Automatic antifreeze filling system, automatic liquid recovery system
Дополнительно 220V 60HZ three-phase 400V 50HZ three-phase 440V 60HZ three-phase
Дополнительно Temperature extended to -40℃~+135℃
Ремарка The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used.
Материал оболочки Cold rolled sheet spraying (standard color 7035)

Модель KRYZ-475W/2T KRYZ-4A15W/2T KRYZ-4A25W/2T
Диапазон температур -40℃~+100℃
Точность контроля температуры ±0.1℃ ±0.1℃ ±0.1℃
Обратная связь по температуре Pt100 Pt100 Pt100
Отображение температуры 0.01k 0.01k 0.01k
Flow output 1~25 L/min 1~25 L/min 1~25 L/min
About traffic description When the temperature is below -30 degrees, the flow rate is controlled within 80% of the maximum value.
Flow control accuracy ±0.1 L/min ±0.1 L/min ±0.1 L/min
Fluid output groups 2 groups 2 groups 2 groups
Pressure control per group 0.2bar~2.5bar 0.2bar~2.5bar 0.2bar~2.5bar
Flow Pressure Description The device can control flow or pressure independently. Different solutions are required for simultaneous control (customization required)
Heating capacity kW 7.5*2 10*2 15*2
Cooling capacity kW 100℃ 7.5*2 15*2 25*2
20℃ 7.5*2 15*2 25*2
0℃ 7.5*2 15*2 25*2
-20℃ 4.5*2 8.5*2 14*2
-35℃ 1.8*2 4*2 6.5*2
Компрессор Inverter scroll compressor
Метод дросселирования Электронный расширительный клапан
Маслоотделитель Эмерсон
Фильтр-осушитель Danfoss
Испаритель Пластинчатый теплообменник
Циркуляционный насос Variable frequency magnetic drive pump
Flow rate, pressure Electromagnetic flowmeter, pressure value 4~20mA
Вход, дисплей 7-inch color touch screen, PLC controller
Communications Modbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet TCP/IP protocol
Защита безопасности It has self-diagnosis function; refrigerator overload protection; high pressure switch, overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other safety protection functions.
System The entire system is a fully closed system. There will be no water vapor at high temperatures and no absorption of moisture in the air at low temperatures. The system will not cause pressure to rise due to high temperatures during operation, and will automatically replenish heat transfer media at low temperatures.
Хладагент R404A/R507C/R125/N40 four refrigerants can be used
External output interface size There are 2 sets of inlet and outlet ports, G3/4
Water cooled @25℃ 4000 Л/ЧАС
ZG1
8000 Л/ЧАС
DN32
12000 Л/ЧАС
DN40
Конденсатор с водяным охлаждением The water equipment condenser of this product adopts plate heat exchanger, which requires water supply from chiller or low hardness tap water, and requires water purification filter
Размеры см 80*120*185 100*150*185 200*145*205
Power supply 380V50HZ 28 кВт 45 кВт 70kW
Вес 660KG 850 кг 1350kg
Standard Automatic antifreeze filling system, automatic liquid recovery system
Дополнительно 220V 60HZ three-phase 460V 60HZ three-phase
Дополнительно Temperature extended to -40℃~+135℃
Ремарка The external circulation pipeline should have a diameter of DN15 or DN20. The pipeline needs to be well insulated, and high-temperature resistant rubber and plastic insulation pipes can be used.
Материал оболочки Cold rolled sheet spraying (standard color 7035)

The equipment can meet the direct cooling/direct heating for battery pack and vehicle testing and testing. This equipment is mainly used for cooling and heating capacity testing. It uses variable frequency compressor with adjustable output; variable frequency fan with adjustable speed and heat dissipation; with high-precision temperature, pressure, flow sensors and built-in software, it can calculate heat exchange capacity in real time, automatically recycle and refill refrigerators, etc. It can meet the needs of battery packs of different sizes.

Отправьте нам сообщение о продукте
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Вас также могут заинтересовать эти продукты

  • Инвертор LTZ серии M"      /&gt;<figcaption><span>APPLICATIONS Suitable for application to the target temperature control object already has a cold storage tank and a circulating pump, and the medium is transported into the LTZ M series refrigeration temperature control unit through th…</span></figcaption></figure></a></div><div class=Инвертор LTZ серии M

    APPLICATIONS Suitable for application to the target temperature control object already has a cold storage tank and a circulating pump, and the medium is transported into the LTZ M series refrigeration temperature control unit through th…

  • LN -60°C~ -10°C"      /&gt;<figcaption><span>适用范围 Характеристики продукта 产品参数 Параметры продукта 行业应用 ПРИМЕНЕНИЕ 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...</span></figcaption></figure></a></div><div class=LN -60°C~ -10°C

    适用范围 Характеристики продукта 产品参数 Параметры продукта 行业应用 ПРИМЕНЕНИЕ 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全、可靠性和...

  • LT -80℃~-20℃"      /&gt;<figcaption><span>It can guarantee 24-hour continuous operation Circulating refrigeration of ethylene glycol mixed with water mixture 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Cir…</span></figcaption></figure></a></div><div class=LT -80℃~-20℃

    It can guarantee 24-hour continuous operation Circulating refrigeration of ethylene glycol mixed with water mixture 1. Can use ethylene glycol mixed with water for circulating refrigeration, saving resources 2.Cir…

загрузка...

已经是到最后一篇内容了!