Камера для ударных испытаний с двумя ящиками
- Heating rate of preheating zone(No load) 5 ℃/min (customizable for 10-25 ℃)
- Cooling rate of pre cooling zone (No load) 2 ℃/min (customizable for 5-25 ℃)
- Pre cooling area Pre cooling range-10℃~-55℃
- Preheating area preheating range+60℃~+180℃
- Колебания температуры≤1℃
The test basket of the double-chamber cooling and heating shock test chamber is mobile when conducting high and low temperature shock tests. The high and low temperature shock conversion is mainly completed by moving the test basket up and down in the high temperature zone and the low temperature zone. The impact recovery time of the double-chamber type is shorter than that of the three-chamber type.
Детали конфигурации
Модель | GD-200-2-B-CJ | GD-400-2-B-CJ | |
Inner box size (W*H*D)cm |
60*60*60 | 90*65*70 | |
Shock temperature range | Low temperature | -40~0℃ | |
High temperature | +60~+150℃ | ||
Preheating zone heating rate | (no load) 5℃/min (10~25℃ can be customized) | ||
Precooling zone cooling rate | (no load) 2℃/min (5~25℃ can be customized) | ||
Precooling area precooling range | -10~-55℃ | ||
Preheating range of preheating zone | +60~+180℃ | ||
Dwell time | ≥30min | ||
Recovery time | ≤5min Recover to within ±2℃ | ||
Колебания температуры | ≤1℃ | ||
Dwell time | ≥30min | ||
Conversion time | ≤10S | ||
Window size (cm) | 300*450 | ||
Хладагент | R404A/R23 | ||
Нагреватель | Electric heating | ||
Air-cooled condenser | Fin heat exchanger | ||
Конденсатор с водяным охлаждением | Jacket/shell and tube heat exchanger | ||
Air circulation | Extended shaft motor, stainless steel centrifugal fan blades | ||
Метод охлаждения | Cascade Refrigeration | ||
Компрессор | Brand inverter compressor | ||
Control method | Segmented fuzzy PID algorithm control | ||
Communication protocol interface | TCP/RS485 (CAN can be customized) | ||
Панель управления | 7-дюймовый цветной сенсорный экран, отображение температурной кривой\EXCEL экспорт данных | ||
Sensor | PT100A grade platinum resistor | ||
Protective devices | Heater dual temperature protection, refrigeration system protection and electrical overcurrent and overload protection, etc. | ||
Outer box size (W*H*D)cm |
149*219*257 | 179*239*257 | |
Электропитание | 380V 50HZ | ||
Insulation material | Glass fiber wool & polyurethane | ||
Inner box material | SUS304 stainless steel | ||
Outer box material | Cold rolled steel plate + plastic spraying | ||
Execution meets standards | GB/T 2423.1、GB/T 2423.2、GJB 150.3A、GJB 150.4A、GB/T 5170 |
Вас также могут заинтересовать эти продукты
Серия преобразователей частоты SUNDI Z
Ультравысокотемпературная технология охлаждения может напрямую охлаждать от высокой температуры 300℃[потому что только теплоноситель в расширении...
СУНДИ -10℃~150℃
Полностью закрытая система, одна среда завершает охлаждение и нагрев -120~350℃ ±0,5℃ переменного тока 380V 50HZ 8кВт макс Ультра высокая температура охлаждения технология может непосредственно охлаждать от...
СУНДИ -80℃~250℃
● Рабочие температуры от -120°C до +350°C ● Ранее недостижимая производительность ● Интеллектуальный контроль температуры ● Максимальная стабильность и воспроизводимость процесса ● Пластинчатый теплообменник Adop, трубопроводный нагрев, быстрые...