Maintenance principle of fluorinated liquid TCU temperature control system
The working environment of the fluorinated liquid TCU temperature control system

Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place;
(2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m;
(3) The louver holes on both sides of the fluorinated liquid TCU temperature control system must not be obstructed or blocked
- After each use of the fluorinated liquid TCU temperature control system, it is necessary to wipe all kinds of stains, oils and solvents on the surface of the machine with a soft cloth to keep it clean;
3. If the fluorinated liquid TCU temperature control system has been used for more than six months, or the high/low pressure switch often fails, or the cooling capacity is reduced, the condenser needs to be cleaned;
4. If it is not an emergency, it is not allowed to close the fluorinated liquid TCU temperature control system by cutting off the main power supply; if the fluorinated liquid TCU temperature control system is not used for a long time in winter, first close the fluorinated liquid TCU temperature control system, and then close the main power supply. And drain the water in the system;
5. Try not to tighten the interface of the fluorinated liquid TCU temperature control system too tightly, and keep regular activities to avoid being locked;
6. Pay attention to observe the condition of the heat transfer oil in the TCU temperature control system of the fluorinated liquid. If there is any color change, you need to contact the heat transfer oil manufacturer;
7. When maintaining the TCU temperature control system of fluorinated liquid, it is necessary to purchase qualified accessories, and do not replace them at will, so as not to cause a fatal blow to the machine.


Электронная почта: sales@cnzlj.com
WhatsApp: 086 13912479193
Похожие рекомендации
-
What are the factors related to the selection of heating and refrigeration circulators?
996Heating and refrigeration circulators are used in many laboratory projects. They are usually equipped with reactors and reactors for cooling, heating and temperature control. Then, what factors are related to the selection of heating and cooling i...
Посмотреть детали -
New energy automobile motor comprehensive test system
1146When the LNEYA new energy vehicle motor integrated test system is running, the control panel settings are required. At the time of setting, if the user does not know how to use it, you can check the manual for use. The indicator of the new energy ...
Посмотреть детали -
High-pressure failure of stainless steel cryogenic refrigerator
1292At the high speed of the stainless steel cryogenic refrigerator compressor, the temperature rises and the compressor generates high air pressure, which causes the high voltage protection relay to operate. The discharge pressure of the compressor r...
Посмотреть детали -
VOCS condensation price and maintenance instructions
1006The performance of VOCS condensing equipment is closely related to the VOCS condensing price. The proper VOCS condensing equipment is definitely superior in performance. What should be paid attention to in the maintenance of VOCS condensing equipm...
Посмотреть детали