Инструкция по очистке труб морозильника 10hp
Морозильник 10 л.с. - это промышленное холодильное оборудование от компании LNEYA. В процессе охлаждения с помощью чиллера, если трубопровод не очищен должным образом, будет использоваться холодильник, поэтому необходимо провести очистку трубопровода. Снимите...
Remove the heat transfer medium before cleaning the 10hp freezer. Connect a suitable drain to the drain and allow it to flow into a suitable container (make sure the tube and container match the heat transfer media). Open the drain valve, the heat transfer medium flows from the external application to the pump chamber and then flows from the drain port to the container at low temperature to remove the heat transfer medium. Be sure to take protective measures to prevent low temperature frostbite. Open the freezer filling port and carefully purge the heat transfer medium in the system by carefully blowing nitrogen into the heat transfer medium outlet (pressure below 3BAR).
Replace 10hp freezer heat transfer oil / internal cleaning, please be careful not to use acetone as a cleaning solvent. Failure to do so will destroy the tightness of the 10hp freezer. After discharging according to the previous section, depending on the heat transfer medium, a lot of residue of the heat transfer medium remains in the pump chamber and the inner container. Fill in a suitable solvent, such as a silicone oil cycle to clean the internal components, including the pump chamber, internal vessels, conduits, etc. Depending on the situation of the contamination, it may be necessary to repeat this method several times. Then let the instrument open all the drain valves and connections. Please note that before using the new heat-conducting medium to control the temperature in ultra-low temperature operation, please be sure to remove the moisture in the system. Otherwise, the viscosity of the heat-conducting medium will increase when the temperature is low, and the heat transfer capacity will be reduced.
When cleaning the 10hp freezer pipe, be careful that the heat transfer medium must be cleaned, otherwise the media will cause the freezer to malfunction.

Похожие рекомендации
-
Микросхема управления низкотемпературным нагревом и другие методы обнаружения
1165With the research and development of chip technology, chip detection technology is also maturing. LNEYA's low-temperature heating control chip technology is applied in chip detection. In addition to this type of detection technology, there are oth...
Посмотреть детали -
LNEYA temperature control system AH series commentary
1145Refrigeration heating temperature control system AH series, suitable for high heat release, suitable for SUS reactor, temperature difference > 150 ° C, can quickly cool high temperature reaction, polymerization reaction and rapid heating and co...
Посмотреть детали -
Описание выбора типа и классификации криогенных охладителей мощностью 40 ГВт
1169Если разные предприятия и разные отрасли промышленности предъявляют разные требования к криогенным холодильникам Wuxi Guanya 40GW, то и выбор модели также отличается. Поэтому лучше иметь четкое представление о потребностях при выборе криог...
Посмотреть детали -
Преимущества низкотемпературного охлаждающего рециркуляционного чиллера
905Низкотемпературный охлаждающий рециркуляционный чиллер представляет собой вид холодильного оборудования с использованием компрессора, а циркуляционный насос обеспечивает источник холода для поддержания температуры в диапазоне от - 2 5℃ до 30 ℃. Рециркуляционный охладитель занимает мало места...
Посмотреть детали