-80 °C производитель холодильника рабочие точки оборудования
Когда пользователь выбирает холодильник -80 °C, он, безусловно, должен иметь надежное качество. Холодильник Wuxi Guanya (LNEYA)-80 °C должен быть внимательным к деталям его работы во время эксплуатации, чтобы избежать поломки оборудования, вызванной воздействием...
The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. – It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.
Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.
-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.

Похожие рекомендации
-
Benefits of using heating and cooling equipment in the laboratory
1188Laboratory heating and cooling equipment (also known as: cold and heat integrated machine, refrigeration and heating cycle device) is a device that integrates cooling and heating, heating and cooling can be quickly converted, and the same medium (...
Посмотреть детали -
How to eliminate the failure of large thermal shock test chamber?
1025As technology continues to advance and improve, LNEYA recommends strict requirements for operators of large thermal shock test chambers. If used improperly, operators need to be able to face and resolve these problems in a timely manner. A large t...
Посмотреть детали -
Control method for semiconductor test chiller to meet temperature requirements
1082The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronic...
Посмотреть детали -
Преимущества чиллера с водяным охлаждением, которые необходимо знать
1158Промышленные холодильники можно разделить на водоохлаждаемые и воздухоохлаждаемые в зависимости от типа охлаждения. Теплообменной средой в чиллерах с водяным охлаждением является вода.Компания LNEYA разработала и внедрила новый тип терморегулятора...
Посмотреть детали