Large temperature difference freezer refrigerant charging instructions
In the development of modern industry, large temperature difference freezer is also important in cold treatment. In the whole process of large temperature difference freezer refrigeration, refrigerant charging is also more important. So how do you charge?
For large-temperature-difference freezer refrigeration systems without high-pressure reservoirs and low-pressure vapor-liquid separators, the control of refrigerant charge is particularly important. Because the refrigeration system is a condenser and also acts as a high-pressure reservoir, the refrigerant is stored in the condenser, and the condenser is cooled. The heat dissipation area is reduced and the condensing pressure is increased, resulting in a decrease in cooling capacity.
For the control of the refrigerant charge of such a large temperature difference freezer, during the charging process, the temperature of the condenser casing should be touched, the upper outlet of the condenser outlet is heated, and the outlet below the outlet is cool (heating) It is indicated that there is a high-temperature exhaust gas of the compressor condensing inside, and the cooling is cold, indicating that the water-cooled large temperature difference refrigerator is a liquid space). Secondly, look at the suction pressure, which corresponds to the temperature of the refrigerant water in the evaporator (that is, corresponds to the evaporation temperature). Then, depending on the return temperature of the compressor of the large temperature difference refrigerator, the return pipe of the high temperature unit should be cooled and dew, but it can be dew condensation to the compressor return valve. The return pipe of the low temperature unit should be frosted, but the frost is compressed. The machine return valve is fine. If condensation or frost builds up on the compressor casing, liquid refrigerant will enter the crankcase, causing the compressor to run oil and liquid. For hermetic compressors, the motor terminals are also shorted. Although most of the closed unit terminals are sealed with a sealant, the possibility of a short circuit still exists due to the uncertainty of the sealing effect.
The above is the refrigerant charging method of Wuxi Guanya LNEYA finishing, hope to help everyone to run a large temperature difference freezer.

Похожие рекомендации
-
How To Vacuum The Ultra-Low Temperature Freezer Refrigeration System?
1073LNEYA ultra-low temperature freezer indoor and outdoor connection has been completed, observe the oil pump oil mark indication to see if there is enough oil, and then start the vacuum pump to see if it is normal. Then unscrew the large valve back ...
Посмотреть детали -
Explosion-proof high and low temperature integrated machine advantage
1185Explosion-proof high and low temperature integrated machines are used in the current pharmaceutical and chemical industry. The heat transfer medium of the entire circulation system is a fully closed cycle, the circulation system has a liquid expan...
Посмотреть детали -
Описание разработки системы тестирования вафельных микросхем
976With the development of the semiconductor industry, the wafer chip test machine has also made great progress. How much do you know about the development of the wafer chip test machine? The integrated circuit industry has gradually emerged since th...
Посмотреть детали -
Выбор оборудования для тестирования батарейного модуля Описание ошибок
1034Многие компании, производящие аккумуляторные модули, имеют определенные заблуждения относительно оборудования для тестирования аккумуляторных модулей LNEYA. Существуют некоторые ошибки при выборе модели оборудования для тестирования батарейных модулей, поэтому постарайтесь выбрать оборудование для тестирования батарейных модулей. Избегайте некоторых ми...
Посмотреть детали