Экологическое описание большого промышленного морозильного конденсатора
В промышленном холодоснабжении одним из наиболее часто используемых видов оборудования являются большие промышленные морозильные камеры. Среди них конденсатор является одним из основных компонентов, и его производительность очень важна. Поэтому при выборе каждый должен понимать,...
When the large industrial freezer system is in operation, the reason for the change of the condensing temperature is the change of the temperature of the cooling medium. The temperature of the condensing depends on the heat transfer area of the condenser, the temperature of the cooling medium, the purity and sufficient amount of the refrigerant, and the compressor. Exhaust temperature and displacement, etc. In normal operation, the condensing temperature and pressure are basically stable, and the space can be adjusted. It is often caused by a system failure (such as sudden water cut or improper number of condensers), causing the machine to malfunction. In operation, it should be checked frequently and found. When you have a problem, you should find the cause and solve it in time to avoid the more serious the damage to the machine.
The temperature environment of different types of condensers for large industrial freezers is different. The condensation temperature of vertical, horizontal shell and shower condensers is 4-6 °C higher than that of cooling water, and the condensation of evaporative condensers The temperature is 5 to 10 ° C higher than the wet bulb temperature of the outdoor air in summer, and the temperature of the air-cooled condenser is 8 to 12 ° C higher than the air temperature.
In Wuxi Guanya LNEYA large industrial freezer refrigeration system, the external heat release of the refrigerant is the normal operation of the condenser. After the high temperature gas discharged from the compressor enters the condenser, the heat is transferred to the medium (water or air), the refrigerant. The steam is cooled and condensed into a liquid, and the liquefied refrigerant enters the evaporator through throttling, thereby achieving the purpose of repeated cycle refrigeration of the industrial explosion-proof large-scale industrial refrigerator. If the accumulator and the condenser are installed in the large industrial freezer at the same height, the outlet pipe at the bottom of the condenser needs to be bent upward to the upper part of the accumulator. This may cause the liquid seal to appear in the pipe. The exhaust function of the compressor, once there is a certain liquid level in the reservoir, will reduce the condensation area of the condenser, increase the condensation temperature and pressure, increase the power consumption, and cause the operating conditions of the freezer refrigeration system to be poor.
The condenser and the accumulator in the large industrial freezer are one of the most important accessories. The above accessories knowledge hopes that everyone can understand clearly.

Похожие рекомендации
-
What should I pay attention to when choosing an evaporator for an ultra-low temperature chiller?
1089The evaporator in the ultra-low temperature chiller is one of its four major components, so performance is more important. The selection of ultra-low temperature chillers needs to pay attention to the influence of liquid level on the evaporation t...
Посмотреть детали -
Инвестиции в рынок установок для улавливания газового конденсата с добавлением летучих органических соединений для создания "зеленой" энергетики в отрасли
1071В последние годы, в связи с ухудшением состояния атмосферы и различными экологическими проблемами, люди уделяют все больше внимания выбросам летучих органических газов в атмосферу. Летучие органические соединения, также известные как ...
Посмотреть детали -
Misunderstanding about the operation of the factory boiler
910The boiler is a very common equipment in the factory. LNEYA Xiaobian tells everyone that many people have misunderstandings about it. Misunderstanding 1 The higher the steam pressure, the better. The choice of boiler steam pressure depends mainly ...
Посмотреть детали -
Precautions for operation of ethylene glycol utra-low temperature chiller at minus 30 degrees
1063The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly,...
Посмотреть детали