What should I pay attention to when choosing an evaporator for an ultra-low temperature chiller?
The evaporator in the ultra-low temperature chiller is one of its four major components, so performance is more important.
The selection of ultra-low temperature chillers needs to pay attention to the influence of liquid level on the evaporation temperature. Due to the influence of the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.

If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. In the subsequent flow of the refrigerant, the temperature of the refrigerant is low, and the possibility of freezing is high. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as 0°C. However, for safety reasons, the temperature of the inner wall of the pipe at the outlet end of the next process is usually kept above 0.5°C. In the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant by more than 1°C.
When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.
According to different models, the choice of evaporator is different. For example, the box-type small ultra-low temperature chiller uses a water tank coil type evaporator; the open-type small ultra-low temperature chiller and the screw-type small ultra-low temperature chiller use shell and tube Type evaporator; for acid and alkali resistant ultra-low temperature chillers, you can choose titanium tube evaporator or stainless steel plate exchanger; there are many options, of course, it can be customized according to user needs.
The ultra-low temperature chiller evaporator is generally designed and equipped by the ultra-low temperature freezing test manufacturer. It is recommended that users check the configuration problems when choosing the ultra-low temperature chiller manufacturer.
Похожие рекомендации
-
Compressor key protection of reactor temperature control system
1285In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor. Under normal working conditions, the compressor of the temper...
Посмотреть детали -
LNEYA isolation explosion-proof cooling heating circulation system SR-35N
663LNEYA isolation explosion-proof cooling and heating circulation system mainly uses heat transfer medium for heating and refrigerant for cooling. So what are the main accessories in the isolated cold and hot water circulation system? What effect do...
Посмотреть детали -
Cooling and shrinking assembly freezer for metal parts and common assembly methods in the industry
1563In the cold shrink production of copper sleeves, bearings, etc., quick-freezing cryogenic boxes are widely used in mechanical assembly. Copper sleeve cooling shrink assembly cabinet variable temperature assembly method is to heat the hole or cool ...
Посмотреть детали -
Chip high and low temperature aging test box system design
1074The high and low temperature aging test box of the chip is applied to the high and low temperature test industry of the chip. The design schemes provided by the high and low temperature aging test box manufacturers of different chips are different...
Посмотреть детали