Core Maintenance Points of Ten High and Low Temperature Test Chamber Manufacturers
According to many years’ production experience of high and низкотемпературная испытательная камера in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and низкотемпературная испытательная камера. As one of the top ten manufacturers of high and низкотемпературная испытательная камера, Wuxi Guanya has sorted out the relevant maintenance points, and everyone pays attention to the analysis.
Enterprise users need to have a comprehensive understanding of the products of ten manufacturers of high and низкотемпературная испытательная камера before choosing. Because of the lack of correct judgment and sufficient recognition, enterprises can not choose high-quality high and низкотемпературная испытательная камера. Among them, compressors, controllers, electronic devices, boxes and hardware fittings are very important, so the role of each component is very important and nursing is very important.
Cleaning of waterway and humidifier
If the waterway of the high and низкотемпературная испытательная камера is not smooth, the scaling of the humidifier will easily lead to the dry burning of the humidifier, which may damage the humidifier. Therefore, the high and низкотемпературная испытательная камера must be cleaned regularly for the waterway and the humidifier.
Selection of Test Environment
Generally speaking, the box of high and низкотемпературная испытательная камера is relatively high. Ten manufacturers of high and низкотемпературная испытательная камера suggest that it should be placed in a benign temperature environment when using. For laboratories that do not meet this requirement, it is necessary to equip with appropriate air conditioners.
Clean evaporator regularly
Many small particles such as dust will condense on the evaporator under the forced air circulation of the test sample in the high and низкотемпературная испытательная камера. It needs to be cleaned regularly in the high and низкотемпературная испытательная камера, otherwise it will seriously affect the normal use of the equipment.
Clean condenser regularly
The common high and низкотемпературная испытательная камера usually uses air-cooled cooling compressor, so it is necessary to repair the condenser fan regularly and remove the dirt and dust from the condenser so as to obtain good ventilation and heat transfer performance.
These high and низкотемпературная испытательная камера ten manufacturers collated the relevant maintenance knowledge, you can pay attention to check the early formulation of maintenance plan.
Похожие рекомендации
-
Сотрудничество с сильными! Церемония подписания стратегического сотрудничества LNEYA&Siemens завершилась успешно
2640On May 25, 2021, the signing ceremony of strategic cooperation between LNEYA Constant Temperature Refrigeration Technology Co., Ltd. and Siemens (China) Co., Ltd. was held in Wuxi, China. At the signing ceremony, leaders such as Que Yaoyao, direc...
Посмотреть детали -
Каковы области применения паровых циркуляторов в химической промышленности?
991Паровой циркулятор в химической промышленности - это оборудование для контроля температуры в фармацевтической и химической промышленности. При работе пользователям необходимо знать характеристики и правила обслуживания, чтобы эксплуатировать оборудование в соответствии с...
Посмотреть детали -
What should I pay attention to when replacing a water-cooled chiller compressor
1035Once the compressor of the water-cooledchiller fails, the compressor needs to be replaced in time, but the replacementof the compressor is not as simple as imagined.Before the water-cooled chiller compressoris replaced, the reasons for the dama...
Посмотреть детали -
What should I pay attention to when the price of 5p refrigeration units is too low?
9745p refrigeration units are commonly used refrigeration equipment in various industries. Users will definitely consider the price factor when they purchase. However, Wuxi Guanya (LNEYA) reminds everyone that there are certain differences between th...
Посмотреть детали