Описание испытаний воздушной системы полупроводникового холодильного отопительного цикла
There are many test items in the refrigeration and heating circulating air system for semiconductors. So, how much do users know about out-of-channel testing?
The out-of-channel test of the cooling and heating circulating air system for semiconductors refers to the measurement of the frequency bands outside the system frequency. The out-of-channel test is to sample the distortion or interference in the system frequency band, instead of testing the transmission frequency itself. The adjacent channel power ratio (ACPR) test ensures that the transmitter is not interfered by adjacent or spaced channels. ACPR is the ratio of the average power of adjacent channels to the average power of the transmitted channel. Measurements are typically made between channels that are separated by multiple channels (between adjacent channels or spaced channels). When performing ACPR testing, it is important to consider the statistical nature of the transmitted signal, because even for the same transmitter, different signal statistics can result in different ACPR test results. For different standards, the test will usually have different names and definitions.
The cooling signal of the cooling and circulating air system for semiconductors is caused by a combination of different signals in the transmitter. The amplitude of such a signal in the system band must be less than the level specified by the standard to ensure that it has less interference to other communication systems. Harmonics are signal distortions caused by the nonlinearity of the transmitter, and the frequencies of these signals are all integer multiples of the carrier frequency. The test of out-of-channel clutter and harmonics is used to ensure that the interference of this channel to other communication systems is small.
The function of the receiver is basically the reverse process of the transmitter, so the test challenges they bring are also very similar. The receiver must successfully capture the RF signal under potentially interfering conditions, so a front-end selection filter must be used to filter out or attenuate signals outside the system band received by the antenna. The low noise amplifier (LNA) amplifies the amplitude of the target signal, but at the same time ensures that the noise amplitude is increased as little as possible. The downconverter converts the RF signal to a lower frequency intermediate frequency signal by mixing with the local oscillator signal. The mixer’s output signal then attenuates the unwanted frequency components produced by the mixer or adjacent channels through the IF filter.
After the relevant test users understand, they can run the test. If there are some use problems in the operation, it is recommended to contact the manufacturer for solution.

(Эта статья источник сети, если есть нарушение, пожалуйста, свяжитесь с удалить, спасибо).
Похожие рекомендации
-
Другое название взрывозащищенного холодильника: металлическая монтажная коробка для обработки холода
1130Взрывозащищенный холодильник Wuxi Guanya LNEYA использует одномашинную технологию самостоятельного складывания криогенной обработки. Он изготовлен из проволочной пластины из нержавеющей стали SUS304 с отдельной низкотемпературной коробкой, горизонтальной низкотемпературной коробкой, внутренним и внешним б...
Посмотреть детали -
Что нужно учитывать при выборе теплообменника для водяного цикла охлаждения автомобильной батареи?
971The car battery cooling water circulation machine has always been one of the most popular equipments. The design of the heat exchanger piping also needs to be designed. What aspects should be considered? There are many types of heat exchange equip...
Посмотреть детали -
Operation and maintenance of chiller cooling system for alternating high and low temperature tests
1108The operation method of the chiller cooling system for alternating high and low temperature tests: 1. Confirm whether the state of the relevant valves in the unit meets the start-up requirements. 2. Supply power to the electrical control device o...
Посмотреть детали -
Как низкотемпературный охладитель подходит для производства пресс-форм?
933Всем известно, что низкотемпературные охладители используются довольно широко, особенно в производстве пресс-форм. Когда низкотемпературный охладитель используется для охлаждения пресс-формы, пресс-форма обычно охлаждается вместе с термопластавтоматом. ...
Посмотреть детали