Как низкотемпературный охладитель подходит для производства пресс-форм?
Everyone knows that the use of low temperature chillers is relatively extensive, especially in the mold industry.
When the low temperature chiller is used to cool the mold, the mold is generally cooled together with the injection molding machine. Generally speaking, the mold is equivalent to a heat exchanger, and the heat is transferred from the mold to the mold and then from the mold to the cooling medium for cooling. Everyone knows that mold molding is inseparable from the function of cooling. When choosing a low-temperature chiller, try to choose a low-temperature chiller with better quality and higher cost. The relative operating power is higher than that of ordinary ones. If the low temperature chiller is used, it can increase the certain output and achieve a certain profit in a long time.
In the practical application of low temperature chillers and molds, the temperature difference of ice water at the inlet is determined according to the product requirements. In many cases, the temperature difference is 3-5 degrees, which is more ideal. The smaller the temperature difference, the more The same amount of ice water required for the same heat to take away, on the contrary, the required flow is very small.
In addition, when using a low-temperature chiller, it is necessary to continuously check the water quality of the low-temperature chiller. Once the water quality changes for a long time, it will cause some corrosion. If it is not treated in time, it will produce scale and can produce a certain separation. Heat, when severe, will reduce the effect of the conversion. Therefore, when configuring a low-temperature chiller, the water quality must be selected well. In addition, the scale can be treated regularly or in a timely manner.
In the process of cooling with a low-temperature chiller, the pressure of ice water should be selected. Of course, our microcomputer function can meet everyone’s requirements and is quite convenient.
Another point is that the pipeline of the low-temperature chiller must be insulated and insulated, otherwise it will cause the loss of cooling capacity, forming dew condensation water on the outer wall, affecting the use of low-temperature chillers.
In fact, when purchasing low-temperature chillers, the more important thing is the quality problem. Since ancient times, it has been a price, since you bought it, you can buy it a little better!
Похожие рекомендации
-
Heat transfer oil of explosion-proof cooling and heating circulator
1536Explosion proof cooling and heating circulator is a commonly used temperature control equipment in laboratories. It is used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors, reactors, etc. ...
Посмотреть детали -
Liquid Cooled Battery Pack BMS Test Cooling Water Circulator
1947As the temperature gradually increases, the use of the cooling water circulator for the BMS test of the liquid-cooled battery pack also gradually peaks. The rated power of the cooling water circulator for BMS testing of liquid-cooled battery packs...
Посмотреть детали -
500 liter reactor cooler selection instructions
1627The 500 liter reactor chiller is used more in the pharmaceutical industry. Therefore, the user needs to select a regular manufacturer when selecting, and at the same time, understand the features and configuration. For the selection of 500 liter r...
Посмотреть детали -
What are the main points for regular maintenance of the recirculating chiller?
1463Recirculating chillers are used frequently in the industry, and the heat generating parts of various devices require recirculating chillers, so operating efficiency is very important. During the running time of the recirculating chiller, it is nec...
Посмотреть детали