Cooling Heating of reactor and material
SUNDI -25℃~300℃- Мощность охлаждения1кВт~200кВт
- Мощность нагрева2.5кВт~200кВт
- Диапазон мощности4кВт~260кВт
- Средняя точность±0.5℃~±1℃
- Точность материала±1℃~±1.5℃
- ХладагентR404A/R507C
- Вес130KG~2250KG
Описание товара

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage
Детали конфигурации
| Модель | SUNDI -225V SUNDI -225WV |
SUNDI -235V SUNDI -235WV |
SUNDI -255V SUNDI -255WV |
SUNDI -275V SUNDI -275WV |
SUNDI -2A10V SUNDI -2A10WV |
SUNDI -2A15V SUNDI -2A15WV |
SUNDI -2A25V SUNDI -2A25WV |
SUNDI -2A38WV |
SUNDI -2A60WV |
SUNDI -2A95WV |
SUNDI -2A130WV |
SUNDI -2A200WV |
|
| Диапазон температур | -25℃~+300℃ | ||||||||||||
| Режим управления | ПИД с обратной связью + наш специальный расчет динамического управления, контроллер ПЛК | ||||||||||||
| Контроль температуры | Управление температурой процесса и модель управления температурой рубашки | ||||||||||||
| Разница температур | Установка или контроль разницы температур между маслом в рубашке и сырьем | ||||||||||||
| Редактор программ | 5 программ, каждая программа может редактировать 40 шагов. | ||||||||||||
| Общение Portocol |
MODBUS RTU Protocol, RS485 interface | ||||||||||||
| Material temp. feedback |
PT100 OR 4~20mA or communication(normal: PT100) | ||||||||||||
| Обратная связь | Температура в трех точках: на входе и выходе оборудования, температура материала реактора (внешний датчик температуры) | ||||||||||||
| Medium temp. acccuracy |
±0.5℃ | ||||||||||||
| Material temp. accuracy |
±1℃ | ||||||||||||
| Heating power kW | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| Охлаждение емкость кВт при |
300℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 |
| 100℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| 50℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| 20℃ | 2.5 | 3.5 | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | 130 | 200 | |
| -5℃ | 2 | 3 | 4.5 | 6.6 | 8 | 12 | 19 | 30 | 46 | 70 | 80 | 125 | |
| -20℃ | 1 | 1.8 | 2.8 | 3.8 | 4.6 | 7 | 12 | 16 | 22 | 32 | 43 | 65 | |
| Circulation pump max Л/мин бар |
20 | 35 | 35 | 50 | 60 | 110 | 150 | 150 | 250 | 400 | 400 | 600 | |
| 1.2 | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
| Насос | magnetic drive pump | ||||||||||||
| Компрессор | Mitsubishi | Emerson copeland vortex flexible | Dorin seni-closed compressor | ||||||||||
| Расширительный клапан | Electronic expansion valve | ||||||||||||
| Испаритель | Пластинчатый теплообменник | ||||||||||||
| Панель управления | 7-inch touch screen,show temp curve\EXCEL data output | ||||||||||||
| Защита безопасности | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
||||||||||||
| Closed circulation система |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||||||||||||
| Хладагент | R404A/R507C, optional: R448A | ||||||||||||
| Размер соединения | ZG1/2 | ZG3/4 | ZG3/4 | ZG1 | ZG1 | ZG1 | DN32 | DN40 | DN50 | DN65 | DN65 | DN80 | |
| Водяное охлаждение type W(@20℃) |
600 L/H |
800 L/H |
1200 L/H |
1600 L/H |
2400 L/H |
3000 L/H |
6 m³/H |
10 m³/H |
12 m³/H |
18 m³/H |
24 m³/H |
36 m³/H |
|
| Размер (water type)cm |
40 *70 *130 |
45 *70 *160 |
55 *70 *175 |
55 *70 *175 |
70 *85 *185 |
80 *120 *185 |
80 *120 *185 |
100 *150 *185 |
200 *145 *205 |
200 *145 *205 |
250 *145 *225 |
300 *160 *225 |
|
| Вес кг | 130 | 180 | 195 | 260 | 320 | 390 | 620 | 820 | 1100 | 1350 | 1680 | 2250 | |
| Питание 380V 50HZ | 4 кВт | 6 кВт | 8 кВт | 11 кВт | 14 кВт | 21 кВт | 34 кВт | 52 кВт | 79 кВт | 123kW | 165kW | 260kW | |
Принцип работы

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Применение: Различные реакторы (микроканальные, стеклянные, реакторы с рубашкой и т.д.), дистилляционные или экстракционные системы, лаборатории, университеты, научно-исследовательские институты, аэрокосмическая, автомобильная промышленность, испытания полупроводников и электрооборудования, химическая, фармацевтическая, нефтехимическая, биохимическая, медицинская, больница, научно-исследовательская мастерская, аэрокосмическая, биологическая и другие отрасли.

Displays Various Information:


1. Отображает все виды температур контроля процесса.
2. Показывает уровень жидкости теплопроводящей среды в расширительном баке.
3. Показывает индикацию работы холодильной системы.
4. Индикация работы нагревателя.
5. Показывает индикацию работы циркуляционного насоса.
6. Отображает управление температурой (материалы, шаблон управления температурой, теплопроводность, среднее управление температурой).
7. Можно установить верхний и нижний пределы регулирования температуры.
8. Можно установить разницу температур между рубашкой и материалом реактора.
9. Показывает сигнал для добавления жидкости, когда она пуста.
10. Холодильный компрессор можно настроить на ручную или автоматическую работу.

Вас также могут заинтересовать эти продукты
Серия преобразователей частоты SUNDI Z
WHATSAPP WECHAT Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion…
SUNDI -10℃~150℃
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ AC 380V 50HZ 8kW max Ultra high temperature cooling technology can directly cool from a hi…
SUNDI -80℃~250℃
● Working temperatures from -120°C to +350°C ● Previously unachievable performance ●Intelligent temperature control ● Maximum process stability and reproducibility ● Adop plate heat exchager, Pipeline heating, the fastest he…
SUNDI-320/320W
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra-high Temperature Cooling Technology Can Directly Cool Down From 300℃ High Temperature. Bec…
SUNDI -25℃~200℃
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ ● Working temperatures from -120°C to +350°C ● Previously unachievable performance ●Intelligent temperature control…
SUNDI -45℃~250℃
● Working temperatures from -120°C to +350°C ● Previously unachievable performance ●Intelligent temperature control ● Maximum process stability and reproducibility ● Adop plate heat exchager, Pipeline heating, the fastest heat…
SUNDI -60℃~250℃
Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with ox…
SUNDI -80℃~250℃
● Working temperatures from -120°C to +350°C● Previously unachievable performance●Intelligent temperature control● Maximum process stability and reproducibility● Adop plate heat exchager, Pipeline heating, the fastest heating…
loading…
已经是到最后一篇内容了!
LNEYA Промышленные чиллеры Производитель Поставщик