Разница между холодильными агрегатами 15P с воздушным и водяным охлаждением
Because the demand conditions are different, when the selected 15P refrigeration unit is air-cooled and water-cooled, what is the difference?
The air-cooled 15P refrigeration unit contains a heat-insulating water tank and water pump in its body, which is very convenient for installation and movement. However, it requires a higher working environment because it is cooled by hot air circulation. Therefore, if the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect of 15 refrigeration units. In addition, if you want to put the refrigeration unit in a dust-free workshop with humidity requirements, then I advise you to modify the water-cooled. Because of the air-cooled refrigeration unit, water vapor is sprayed on the top of the machine to dissipate heat.
The water-cooled 15P refrigeration unit can be divided into open type, sealed type (some called box type) and screw type. It is necessary to declare that the water-cooled refrigeration unit must be additionally equipped with a cooling tower and a water pump for extracting hot water to dissipate heat. In order to achieve a better cooling effect.
Air-cooled 15P refrigeration units can be used on small systems, most of which are water-cooled. When the water is cold, the main engine is less than the air-cooled. In other words, the cooling efficiency of the water-cooled unit will decrease relative to the long-term operation, and the air cooling will not.
The air-cooled 15P refrigeration unit has a slightly higher investment than the water-cooled 15P refrigeration unit, but the annual operating cost is lower than that of the water-cooled refrigeration unit. The construction cost of the equipment room is relatively small in various refrigeration unit cold and heat source systems. The cost is about half the cost of water-cooled or boilers. The noise and volume of air-cooled chillers are larger than those of water-cooled units. This requires attention.
There is a certain difference between the air-cooled and water-cooled units of the refrigeration unit. I hope that you can understand the proper 15P refrigeration unit model.
Похожие рекомендации
-
Maintenance Method Of Ultra Low Temp Chiller Refrigeration System
1692The ultra low temp chiller refers to the refrigeration unit whose chilled water temperature reaches below minus 35℃. The unit adopts two-stage compression refrigeration, and the combination of the scroll compressor and the piston compressor is use...
Посмотреть детали -
Температурный контроль качества и надежности полупроводниковых пластин интегральных схем/чипов
2026Самая основная часть создания микросхемы - это дизайн-лента-упаковка-тестирование. Структура себестоимости микросхемы обычно состоит из 20% трудозатрат, 40% ленты, 35% упаковки и 5% тестирования. Тест на самом деле является наиболее во всех аспектах чипа. "Дешевый" шаг, но...
Посмотреть детали -
Подробное представление оборудования для чиллеров с воздушным охлаждением
1966LNEYA refrigeration накопила более 10 лет опыта применения охладителей. В соответствии с различными областями применения и условиями эксплуатации, она разработала различные типы охладителей, в том числе с воздушным охлаждением...
Посмотреть детали -
Use of cold processing refrigerators for mechanical parts and comparison with liquid nitrogen
1539In the machinery manufacturing industry, the quality requirements for parts are very strict. In order to better improve the performance of machinery, improve product quality and life, a new technology-cryogenic treatment has been produced. During ...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик