The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature chiller system, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
Похожие рекомендации
-
Selection of Temperature Control System for Laboratory Resin Reaction Kettle
15921. Choose from the quality of the laboratory resin reactor temperature control system: can affect the quality of the laboratory resin reactor temperature control system, may be the use of accessories. There are some small factories on the market t...
Посмотреть детали -
-
Control method for semiconductor test chiller to meet temperature requirements
1784The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronic...
Посмотреть детали -
How to Deal with Fault of Conpressor after Cold Plate Freezer for Sale?
1429In the operation of the cryogenic refrigerator refrigeration system, once the compressor fault occurs, it will affect the operation of the cryogenic refrigerator. So what are the faults that affect the compressor? How do clients settle it if the c...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик