TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.
In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
ΠΠΎΡ
ΠΎΠΆΠΈΠ΅ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΈ
-
What do the LNEYA chiller fault codes mean? What is the solution?
2514Q: What is the fault code of the chiller? Answer: E1 means extremely high indoor temperature alarm, E2 means extremely high temperature alarm, E3 means extremely low temperature alarm, E4 means indoor temperature controller failure, E5 means water...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
What are the installation requirements for lithography chillers?
1740In order to ensure the reliable and normal operation of the chiller of the lithography machine and prevent the failure of the chiller caused by improper water distribution pipeline construction, the following matters should be paid attention to wh...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
ΠΠΎΠ³Π΄Π° Π²ΡΠ±ΠΈΡΠ°ΡΡ ΡΠΈΡΡΠ΅ΠΌΡ ΠΊΠΎΠ½ΡΡΠΎΠ»Ρ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ TCU?
1603First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket ...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
ΠΠΎΠ»ΡΡΠΈΠ» ΠΏΡΠ΅ΠΌΠΈΡ "2021 High Quality Development Award".
2550ΠΠΎ Π²ΡΠΎΡΠΎΠΉ ΠΏΠΎΠ»ΠΎΠ²ΠΈΠ½Π΅ Π΄Π½Ρ 8 ΠΌΠ°Ρ 2022 Π³ΠΎΠ΄Π° Π½Π° ΡΠ»ΠΈΡΠ΅ Π₯ΡΠ½ΡΠ°Π½Ρ Π³ΠΎΡΠΎΠ΄Π° Π£ΡΠΈ ΡΠΎΡΡΠΎΡΠ»Π°ΡΡ Π΅ΠΆΠ΅Π³ΠΎΠ΄Π½Π°Ρ ΠΊΠΎΠ½ΡΠ΅ΡΠ΅Π½ΡΠΈΡ ΠΏΠΎ ΠΏΠΎΠ΄Π²Π΅Π΄Π΅Π½ΠΈΡ ΠΈΡΠΎΠ³ΠΎΠ² ΠΈ Π½Π°Π³ΡΠ°ΠΆΠ΄Π΅Π½ΠΈΡ 2020 Π³ΠΎΠ΄Π°. ΠΠΎΠΌΠΏΠ°Π½ΠΈΡ Wuxi Guanya Constant Temperature Refrigeration Technology Co., Ltd. (LNEYA) ΠΏΠΎΠ»ΡΡΠΈΠ»Π° Π½Π°Π³ΡΠ°Π΄Ρ "2020 Outstanding Contribution Award"...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ
LNEYA ΠΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΠ΅ ΡΠΈΠ»Π»Π΅ΡΡ ΠΡΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡΠ΅Π»Ρ ΠΠΎΡΡΠ°Π²ΡΠΈΠΊ