During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out necessary daily maintenance.
Inspection of refrigeration system of glycol chiller: generally, various problems will inevitably occur after long-term use of glycol chiller. Once there is a fault, we should carefully check the service condition of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system, and judge whether their functions are normal. We usually check them through sound and appearance. If there are problems, we suggest to replace them in time.
Refrigerant inspection of glycol chiller: regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of glycol chiller is also different. When the low-temperature chiller works normally, the high-pressure display is 11-17kg and the low-pressure display is 3-5kg.
Inspection of cooling water system of glycol chiller: check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.
System cleaning of glycol chiller: the glycol chiller shall be cleaned once a year after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good refrigeration effect.
Voltage and current inspection of glycol chiller: regularly check whether the voltage and electric flow of glycol chiller are stable and whether the compressor operates normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
Of course, there are many other details that need your attention.
Похожие рекомендации
-
Примечание по применению низкотемпературного холодильника для термоусадочной сборки деталей автомобильного двигателя
1914Engine assembly is carried out in a low-temperature environment below minus 30°C in a low-temperature refrigerator. The mainstream automobile engine manufacturers have their own low-temperature assembly workshops. Engines assembled in a low-temper...
Посмотреть детали -
LNEYA стала лидером в обеспечении живых онлайн-аудитов
2197Good products come from a strict manufacturing process. In March 2020, LNEYA took the lead in adopting the methods of cloud supervision and factory inspection, focusing on the display of LNEYA refrigeration heating temperature control device, TCU ...
Посмотреть детали -
Cryogenic storage tank (explosion proof) chemical cryogenic storage
1801Product Overview:Microcomputer control, multiple security protection, and more reliable operation; Single-compressor automatic cascade supercooling refrigeration technology; compressors use Secop and France Taikang brandContactors and circuit br...
Посмотреть детали -
Benefits of Winterizing and Degassing Prior to Distillation
1532Prior to distilling oil, you should follow a winterization and degassing procedure. The winterization will remove fats, waxes, and other inactive and unwanted compounds. Degassing will remove any solvents and other inactives with low boiling point...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик