The entry point for the selection of industrial chillers
Industrial chillers are refrigeration devices that assemble refrigerators, condensers, evaporators, expansion valves, control systems, and switch boxes on a common base or frame. According to the heat rejection method of the unit, it can be divided into water-cooled and air-cooled chillers. The latter adopts heat pump circulation and is welcomed by users. After fully considering the above factors, what should we pay attention to when choosing a chiller?
The main configuration is:
Compressors, electrical components, water pumps, evaporators, condensers, high/low pressure controllers, high/low pressure gauges, LCD thermostats, expansion valves, antifreeze switches, hand valves, and fans. Screw chillers and high-precision constant temperature circulating chillers are trusted by well-known international and domestic vacuum instruments, analytical instruments, and other manufacturers.
Water circulatory system:
First inject a certain amount of water into the water tank of the chiller, cool the water through the chiller refrigeration system, and then send the low-temperature cooling water to the equipment that needs to be cooled by the water pump. The chilled water will take away the heat and increase the temperature before returning to The water tank achieves the cooling effect. The cooling water temperature can be automatically adjusted according to requirements, and long-term use can save water. Therefore, the chiller is a standard environmentally friendly and energy-saving equipment.
When choosing a chiller, you should also pay attention to the following points:
1. Generally, 2 to 4 refrigeration units are appropriate, 2 for small and medium-sized systems, 3 for larger ones, and 4 for extra-large ones. The possibility of mutual backup and switching between units should be considered. Combination schemes with different types and capacities of different units can be used in the same machine room to save energy consumption. At least one unit with a higher degree of automation, better regulation performance, and high efficiency operation under partial load should be selected among the units operating in parallel.
2. The refrigeration coefficient COP of the electric-driven refrigerator is higher than the thermal coefficient. However, each type of unit has its own characteristics and uses its strengths.
3. For the cold source of a large centralized system, it is advisable to choose a chiller with a compact structure, a small footprint, and a compressor, motor, condenser, evaporator, and automatic control components assembled on the same frame. For small systems, direct evaporative compression condensing units should be used.
4. Use domestically produced units as much as possible. my country’s refrigeration equipment industry has developed rapidly in the past ten years, and most of the product performance is close to the international advanced level, especially the small and medium-sized chillers, which are completely comparable to imported products, and have unparalleled advantages in price. Therefore, under the same conditions, domestic chillers should be selected first.
Похожие рекомендации
-
Semiconductor refrigeration temperature control table cooler operation instructions
1815The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching bet...
Посмотреть детали -
The Application of Cold Plate Freezer
1465The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston compressors, semi-hermetic piston compound compress...
Посмотреть детали -
What are the causes of the blockage of the cooler?
1519The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical conn...
Посмотреть детали -
Maintenance instructions for compressors at minus 85 degrees ultra low temperature freezer
1701The compressor in the ultra-low temperature freezer of minus 85 degrees is one of the main components, and its performance is very important, so maintenance is also very important. For manufacturers of sub-85 degree ultra-low temperature freezer c...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик