Принцип охлаждения низкотемпературного холодильника
The refrigeration principle of the so-called низкотемпературный охладитель is to use the artificial method, compressor refrigeration, through energy consumption, in a cycle process, in the process that cooling materials take away the heat. Generally speaking, the compressor is use to refrigerate. With the refrigerant, the low boiling point material is used as the medium. The refrigerant is compressed in the compressor, the saturation temperature is higher than the ambient temperature, then it passed through the condenser and is condensed into liquid, liquefied through the throttle valve, and then the heat is absorbed by the cold medium to become the low pressure steam, finally it returns to the compressor cycle.
In addition to compressor refrigeration, there is ammonia refrigeration. However, the overall cost of compressor refrigeration is lower than that of ammonia refrigeration. So now, we tend to choose compressor refrigeration.
After understanding the principle of refrigeration, the selection of a series of equipment parameters such as water flow, outlet temperature and cooling capacity of low temperature chiller should be fully understood in order to make a better selection.
Of course, the refrigerants of low temperature chillers can be environmental refrigerants as far as possible, for the sake of more energy saving and environmental protection and in line with the demand of the public.
Похожие рекомендации
-
High and low temperature equipment manufacturers analyze expansion valve knowledge
1119The expansion valve is an important accessory in the high and low temperature integrated machine. The manufacturer tells you that there are various kinds of expansion valves, and different expansion valves have different differences. The high and ...
Посмотреть детали -
Maintenance of the condenser of high and low temperature circulation device
1188The condenser in the high and low temperature constant temperature circulation device is one of the accessories in the refrigeration process, and its performance is very important. LNEYA reminds the user that regular maintenance is required after ...
Посмотреть детали -
Closed cycle heating system temperature deviation description
933If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time. In the steady state, the closed loop heating system displays th...
Посмотреть детали -
How to purchase a power management chip temperature test system?
1251The power management chip temperature test system is an important equipment used to test the performance and reliability of semiconductor chips in different temperature environments. When purchasing this type of test equipment, you need to...
Посмотреть детали