Introduction To The Preparation Of Low Temperature Chiller’ Operation
Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.
Before running the низкотемпературный охладитель, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.
Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.
Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%–100%, then 100%–0%, then manually stop the oil pump.
Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 –55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.
With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.
Похожие рекомендации
-
Этапы отладки промышленного водяного охладителя в химической промышленности
904After completing the installation of industrial water chillers in chemical enterprises, certain debugging needs to be carried out in the early stage of operation. Only through careful debugging can we find out whether there are hidden troubles in...
Посмотреть детали -
Вопросы, требующие внимания при замене масла хладагента на заводе по производству винтовых чиллеров
1087The refrigerant oil in the screw chiller factory needs regular inspection and replacement. We all know that different grades of refrigerant oil cannot be mixed together, otherwise it will cause abnormal or strike conditions of the screw chiller fa...
Посмотреть детали -
Взрывозащищенные высокой и низкой температуры одной машины производитель инструкции точки установки
1203После того как взрывозащищенная высоко- и низкотемпературная интегрированная машина доставлена с завода, ее необходимо установить по прибытии на место назначения. На что следует обратить внимание при установке? Взрывозащищенная высоко- и низкотемпературная...
Посмотреть детали -
How to replace the scroll compressor of the impact tester model?
1499In terms of different impact tester models, the configuration is also somewhat different. Among them, special care should be taken when replacing the scroll is a compressor. If the replacement is not noticed, the impact tester cannot be used. The ...
Посмотреть детали