Отказ компрессора системы управления охлаждением из-за давления масла
If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be cleared. Then check whether the compressor of the refrigeration control system is too large due to the opening of the oil pressure regulating valve or the valve core is detached. If the hydraulic pressure regulating valve of the refrigeration control system is improperly adjusted, adjust the oil pressure regulating valve and adjust the oil pressure to the required value. If the valve core is detached, the valve core should be reinstalled and tightened. If there is too little oil in the crankcase of the refrigeration control system or there is refrigerant, the oil pump will not enter the oil. If the oil is too small, it should be timely. Refueling, if it is the latter, stop in time to eliminate the refrigerant. Pay attention to the oil pump. If the oil pump wears out seriously, the clearance will be too large, causing the oil pressure to not come up. In this case, the oil pump should be repaired and replaced directly if the fault is serious. The timely cooling control system checks whether the connecting rod bearing bush, the main bearing bush, the connecting rod small head bushing and the piston pin have been seriously worn, and the relevant parts are replaced in time, and the rear end cover gasket of the crankcase is misplaced, blocking the intake of the oil pump. The oil passage should be disassembled and the position of the gasket should be re-fixed.

Of course, the oil temperature of the refrigeration control system needs to be in the normal range. If the oil temperature is too high, it is necessary to check in time whether the shaft and the tile are improperly assembled, and the clearance is too small. The size of the shaft and tile assembly clearance should be adjusted so that the clearance meets the standard requirements. It is. Next, check the lubricating oil for impurities, which will cause the bearing bush to be pulled. For this, the brushed bushing should be flattened and replaced with new oil. If the tile is severely pulled, replace the new tile. Then check that the shaft seal friction ring is installed too tightly or the friction ring is pulled, and the shaft seal friction ring is re-adjusted in time. If the friction ring is severely pulled, replace the new friction ring. If the suction and exhaust temperatures of the compressor of the refrigeration control system are too high, the system’s liquid supply valve should be properly adjusted to restore the suction and exhaust temperatures to normal.
Overall, the refrigeration control system compressor failure solution is not as simple as imagined, so we need our operators to know more about our refrigeration control system and have enough knowledge to face these faults.
Похожие рекомендации
-
Instructions for use of various components of high and low temperature cycle machine
1175In the high and low temperature cycle machine, each accessory has its own performance advantages. When running, we need to have a clear understanding of each accessory in order to run the device better. The compressor functions to compress and dri...
Посмотреть детали -
16. – 18. June 2020 | The Automotive Testing Expo Europe-LNEYA
1412The Automotive Testing Expo Europe is a trade fair for automotive test, evaluation and quality engineering. It is one of the most important event of its kind in Europe.The fair widtmet the latest technologies and services to improve quality, safet...
Посмотреть детали -
Operation and maintenance of chiller cooling system for alternating high and low temperature tests
1102The operation method of the chiller cooling system for alternating high and low temperature tests: 1. Confirm whether the state of the relevant valves in the unit meets the start-up requirements. 2. Supply power to the electrical control device o...
Посмотреть детали -
Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
1204Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chil...
Посмотреть детали