Recrystallization temperature and influencing factors?
Recrystallization is the process of recrystallizing crystals from a solution or melt after they are dissolved in a solvent or melted. Recrystallization can purify impure substances or separate mixed salts from each other. Among them it is the result of physicochemical action.
Solid material can be purified by recrystallization. Recrystallization of some metals or alloys can refine the grains, or change the crystallization, thereby changing its properties.
The general process of recrystallization purification method:
Selection of solvent – Dissolving solids – Filtration while hot to remove impurities – Precipitation of crystals – Collection and washing of crystals – Drying of crystals
When performing recrystallization, choosing an ideal solvent is a key, and an ideal solvent must meet the following conditions:
(1) No chemical reaction with the purified substance.
(2) A large amount of the purified substance can be dissolved at a higher temperature; while at room temperature or lower temperature, only a small amount of the substance can be dissolved.
(3) The solubility of impurities is very large or very small (the former case is to keep the impurities in the mother liquor and not precipitate with the crystals of the purified product; the latter case is to make the impurities be filtered out during hot filtration).
(4) It is easy to volatilize (the boiling point of the solvent is low), and it is easy to separate and remove from the crystal.
(5) It can form better crystals.
In the operation of recrystallization, the crystal must be dissolved in hot distilled water, must be dissolved in hot solvent, and filtered after cooling.
Solutes have higher solubility when the temperature is higher, and higher solubility when the temperature is lower; if a saturated solution is prepared when the temperature is high, lower the temperature, and the solute will be precipitated in the form of crystals. The amount of impurities is small, and they are still dissolved in the liquid even at low temperatures, so further filtration can achieve the purpose of purification. Therefore, if hot distilled water is not used, it still needs to be heated, and a high-concentration solution must be prepared at high temperature
Strain while hot. Therefore, it needs to be cooled to room temperature or even lower to allow the crystals to precipitate as much as possible before filtering.
Our LNEYA heating system/heating circulator UC series, heating temperature range 50 ℃ ~ 300 ℃, Widely used in petrochemical, chemical, pharmaceutical, bioengineering, life science, Light industry and food,Industry, sample testing and so on. If you If you are interested in our equipment or need to purchase a heating circulator, you can contact us to get a manual for understanding.
Похожие рекомендации
-
Перспективы развития электронных тестовых тепловых систем
1370Для современного общества сохранение энергии и сокращение выбросов также является важной задачей. В процессе развития полупроводниковой промышленности, производства микросхем, интегральных схем и других отраслей, электронная тестовая тепловая система может эффективно проверять температуру...
Посмотреть детали -
Professional introduction and application of cooling circulating water machine
1597The cooling water machine (the chiller, also known as the chiller) is an air-cooled water circulation device that does not require a cold water tower. It is a compressor-cooled design that is designed for machines, scientific instruments, or produ...
Посмотреть детали -
Температурные требования к биореакторам и кристаллизационному оборудованию для фармацевтических процессов
1877Ниже приводится конкретное объяснение температурных требований для обоих типов: Требования к температуре для биореакторов: биореакторы в основном используются для биологических процессов, таких как ферментация и культивирование клеток, где температурный конт...
Посмотреть детали -
Температурный контроль динамической системы управления температурой в технологическом оборудовании
1494In the chemical industry, especially in process engineering, many processes are bound to a temperature, or can be supported by specific temperature control applications, thereby making efficiency higher. An example of the latter is continuous temp...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик











