How to use the reactor thermostat?
The reactor thermostat is generally heated by a resistance wire, cooled by a compressor, and is supplemented with a PID controller to maintain a relatively standard temperature, so as to achieve the purpose of the experiment. The shell is made of metal plate, and the control box is directly installed on the water tank. There are two water inlets and outlets for the condensate pipe next to it, and the water pump is used as the circulating power in the water tank, which solves the problem of uneven warm water and makes the temperature control accuracy of the reactor thermostat and the water uniformity meet higher requirements.
If you are using the reactor thermostat once, you must read the instructions and related materials in detail before using it, and earnestly grasp its structural principles, performance indicators, operating procedures, maintenance and related precautions. Before using the reactor thermostat, you must carefully check whether the connection between the equipment and the external wiring (components) are correct and normal, check whether the power plug is correctly inserted, whether the voltage, frequency, and indicator meet the requirements of the instrument, and check whether the equipment is in a normal state. The liquid medium must be added to the reactor thermostat before use, otherwise the heater will be damaged when it is energized. The liquid level of the medium should be lower than about the worktable.
After the refrigeration switch of the reactor thermostat is turned off, the refrigeration switch should be turned on again at an interval of 10-20 minutes (depending on the ambient temperature). In the event of water, electricity, or gas supply failure or interruption during the experiment, the relevant switches that affect the thermostat equipment of the reactor should be turned off immediately, and protective measures should be implemented. The thermostat equipment of the reactor should be placed in a dry and ventilated place with no obstacles within 300mm around the instrument. When the working temperature of the reactor thermostat is low, care should be taken not to enter the tank to prevent frostbite. After use, all switches are turned off and the power is cut off. The reactor thermostat should be cleaned regularly to keep the work surface and operation panel tidy.
The maintenance and maintenance of the reactor thermostat is the basic requirement for a good thermostat test. Doing a good job in the maintenance and maintenance of the reactor thermostat is related to the intact rate, the utilization rate and the opening rate of the experimental teaching of the reactor thermostat. Experiment success rate. Therefore, as a member of the laboratory, you should understand the general knowledge of the maintenance and maintenance of the reactor thermostat, and master the basic skills of maintenance and maintenance.
Похожие рекомендации
-
CIPM China [C-48-2] welcomes new and old customers!
1956The 58th (Fall 2019) National Pharmaceutical Machinery & ChinaInternational Pharmaceutical Machinery Expo will be held at the Chongqing International Expo Center from November 5th to November 7th, 2019. It is recognized by the industry as prof...
Посмотреть детали -
KRY series water chiller for new energy vehicle quality test
1605The new energy vehicle powertrain test bench can be directly connected to the power output end of the electric drive assembly through the half-shaft. The front end is equipped with high-precision torque sensor and speed sensor to provide high-pre...
Посмотреть детали -
Теплоноситель для систем охлаждения и нагрева в химической и фармацевтической промышленности
1748Система контроля температуры охлаждения и нагрева, также известная как циркулятор высокой и низкой температуры или система динамического контроля температуры, представляет собой оборудование для контроля температуры, используемое в фармацевтической и химической промышленности для обеспечения холода и ...
Посмотреть детали -
ЛНЕЯ: Сосредоточьтесь на каждой детали, чтобы создать блестящий
1897LNEYA использует выдающиеся таланты в области температурного контроля охлаждения и отопления, и имеет сильную техническую базу. Она имеет хорошо известную команду высококлассных исследователей и разработчиков в отрасли. Это высококлассная команда по исследованиям и разработкам и применению ф...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик