How To Choose The Equipment For The Reactor?
The choice of equipment for the reactor needs to be measured by the following points:
1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between.
2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 degrees, equipped with a cooling machine; there is also an oil cooling, suitable for high temperature resin, but the temperature should be greater than or equal to 200 degrees.
3. Material: Generally, there are SUS304 stainless steel, Q235 carbon steel, SUS316 stainless steel, etc.;
4. Stirring method: inclined blade type with inclined angle of 45-60 degrees; anchor type with scraping edge scraping; dispersing disc type with 1000/1500/2800 rpm for shearing (for paint or powder, Hot melt adhesive (rubber); and ribbon type for high viscosity with dispersing disc (for hot melt adhesive)
5. Sealing form: generally has mechanical seal, packing seal, double sealing surface, single sealing surface;
6. Structural aspects: generally have outer half tube type (more than or equal to 2 tons); outer jacket type (more than 3 tons); inner coil; no jacket (no heating); inner coil type (suitable for small viscosity, Small fluidity)).
7. The structure of the kettle body: determined according to size, material and thickness;
Wuxi Guanya LNEYA refrigeration heating temperature control system is the first choice for the reactor equipment, ultra-high temperature cooling technology, can directly cool down from 300 degrees high temperature. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
ΠΠΎΡ
ΠΎΠΆΠΈΠ΅ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΈ
-
ΠΠ΅ΡΡ ΠΏΡΠ΅Π΄ΠΎΡΡΠΎΡΠΎΠΆΠ½ΠΎΡΡΠΈ ΠΏΡΠΈ Π·Π°ΠΌΠ΅Π½Π΅ ΠΎΡ Π»Π°ΠΆΠ΄Π°ΡΡΠ΅Π³ΠΎ ΠΌΠ°ΡΠ»Π° Π² ΡΠΈΡΡΠ΅ΠΌΠ΅ ΠΎΡ Π»Π°ΠΆΠ΄Π΅Π½ΠΈΡ Π°Π²ΡΠΎΠΌΠΎΠ±ΠΈΠ»ΡΠ½ΠΎΠ³ΠΎ Π·Π°ΡΡΠ΄Π½ΠΎΠ³ΠΎ ΡΡΡΡΠΎΠΉΡΡΠ²Π°
1269ΠΠΎ Π²ΡΠ΅ΠΌΡ ΡΠ°Π±ΠΎΡΡ ΡΠΈΡΡΠ΅ΠΌΡ ΠΎΡ Π»Π°ΠΆΠ΄Π΅Π½ΠΈΡ Π±ΠΎΡΡΠΎΠ²ΠΎΠ³ΠΎ Π·Π°ΡΡΠ΄Π½ΠΎΠ³ΠΎ ΡΡΡΡΠΎΠΉΡΡΠ²Π° Π½Π΅ΠΎΠ±Ρ ΠΎΠ΄ΠΈΠΌΠΎ ΠΎΠ±ΡΠ°ΡΠ°ΡΡ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅ Π½Π° ΡΠΎΡΡΠΎΡΠ½ΠΈΠ΅ Ρ ΠΎΠ»ΠΎΠ΄ΠΈΠ»ΡΠ½ΠΎΠ³ΠΎ ΠΌΠ°ΡΠ»Π°. ΠΠΎΡΠ»Π΅ Π·Π°ΠΏΡΡΠΊΠ° ΠΊΠΎΠΌΠΏΡΠ΅ΡΡΠΎΡΠ° Π²Π½ΠΈΠΌΠ°ΡΠ΅Π»ΡΠ½ΠΎ ΡΠ»Π΅Π΄ΠΈΡΠ΅ Π·Π° ΠΈΠ·ΠΌΠ΅Π½Π΅Π½ΠΈΠ΅ΠΌ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ ΠΈ Π΄Π°Π²Π»Π΅Π½ΠΈΡ ΠΌΠ°ΡΠ»Π°. ΠΡΠ»ΠΈ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ° ΠΌΠ°ΡΠ»Π° ΠΌΠ΅Π½ΡΠ΅ΡΡΡ...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
What are the main advantages of oil coolers for the biopharmaceutical industry?
1319In the refrigeration system of the oil cooler in the biopharmaceutical industry, the compressor, the evaporator and the condenser are the indispensable parts of the refrigeration system. The condenser is the equipment that emits heat, which combin...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
The Installation Requirement of the Industrial Chiller
1593(1) The chiller power supply adopts three-phase four-wire, power supply line (R, S, T) connected with power supply fire line, (N) zero line, (G) ground line.,
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
What are the causes of the blockage of the cooler?
1516The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical conn...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ