Maintenance of high and low temperature circulator in the pharmaceutical industry
The high and low temperature circulator in the pharmaceutical industry is also an increasingly common temperature control equipment in all walks of life. It is inevitable that the equipment needs to be maintained after long-term use. How to maintain it to extend its service life?
For the maintenance of the air-cooled high and low temperature circulator in the pharmaceutical industry, the aspects that need attention:
①Please keep the surface of the radiator coil of the high and low temperature circulator in the pharmaceutical industry clean to ensure that the surrounding air is circulating and the temperature is low;
②Regularly clean the dirt on the coil to ensure a good heat exchange effect;
③If the high and low temperature circulator in the pharmaceutical industry has been used for more than six months, or the high and low pressure switches frequently fail, or the cooling capacity is reduced, please arrange for personnel to clean the condenser;
④If the above instructions are repaired for many times, the fault alarm of the high and low temperature circulator in the pharmaceutical industry continues to sound, and the maintenance personnel must be asked to repair the high and low temperature circulator in the pharmaceutical industry;
⑤The air-cooled pharmaceutical industry high and low temperature circulator unit should be turned on according to the correct rotation of the fan. If it can be turned on and run in the forward direction, it means that the power connection has been reversed and the phase sequence must be replaced before starting. The setting values of various protection devices of this machine have been adjusted by the factory, and users should not change them at will.
When the device fails and an alarm is issued and shut down, please press the stop button of the device first, and then check the cause of the failure. Before troubleshooting, do not forcibly start the device. If it is not an emergency, it is not allowed to turn off the equipment by cutting off the main power supply.
In daily use, the high and low temperature circulator in the pharmaceutical industry should be regularly arranged for maintenance workbenches. Regular maintenance can make the high and low temperature circulator in the pharmaceutical industry have a longer service life.
Похожие рекомендации
-
Как контролировать температуру восстановления растворителя дистилляцией?
16211. If the product quality is not affected by the presence of air at a higher temperature, it can be recovered at normal pressure first, and when the temperature exceeds the normal pressure boiling point of the desolvent by 10 degrees, when the so...
Посмотреть детали -
Циркулятор отопления закрытой холодильной установки Ежедневное руководство по обслуживанию
2181The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life. The user...
Посмотреть детали -
Explosion-proof cryogenic refrigeration unit instructions
1583Explosion-proof cryogenic refrigeration units are used in many industries. When users use them, they need to understand their corresponding usage instructions to avoid improper operation and more efficient operation. The energy consumption of the ...
Посмотреть детали -
How to solve the lack of cooling capacity of the semiconductor cooling cycle system?
1718The semiconductor cooling cycle system is a device for cooling the heating part of the semiconductor in the refrigeration equipment. It is commonly used to test semiconductor IC parts, automotive electronic parts, optical fiber components, telecom...
Посмотреть детали