Как справиться с утечкой хладагента при переработке органических отходов?
В процессе обработки органического отработанного газа, если обнаруживается утечка хладагента, рекомендуется своевременно ее устранить. Профессиональный производитель LNEYA по переработке органических отходов анализирует знания о переработке органических отходов...
Organic waste gas treatment VOCS gas single material or multi-material condensation recovery, the main treatment gases are: hydrocarbons such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, Styrene, naphtha, etc.; alcohols, ethers, ketones, esters, etc., in the event of a situation, we must now fill the leak or treatment of the refrigerant leakage, then replace the desiccant, re-vacuum treatment, Fill the appropriate refrigerant. When you find that the leaking refrigerant is partially immersed in water, stop the chiller and quickly remove the water from the tank to prevent the compressor from drawing water into the system for more serious damage.

So, what should be done if the organic waste gas treatment refrigerant is found to be insufficient? Organic waste gas treatment failure phenomenon: the whole vehicle refrigeration effect is poor, the air outlet air is only cool, and the manifold pressure gauge check finds that the high pressure is cut and the low pressure side pressure is low (when the compressor speed is 2000/mim, the ambient temperature is about 35C). The low pressure gauge index is lower than 1kg/CM square, the high pressure gauge index is lower than 10kg/CM square, and the bubble flow is visible from the sight glass.
This may be due to a refrigerant leak point in the refrigeration system, resulting in insufficient refrigerant. Treatment method Use an electronic leak detector to detect the leak point and carry out the replacement or replacement of parts. If the parts are not replaced, only the appropriate amount of refrigerant can be replenished; if the parts are replaced, the appropriate amount of refrigerating oil should be added as required, and the refrigerant should be added after the system is vacuumed.
The above is the relevant treatment of organic waste gas treatment refrigerant leakage. If the Wuxi LNEYA organic waste gas treatment equipment fails, it is recommended to solve it in time!
Похожие рекомендации
-
Cooling simulation system for battery pack extreme performance test
1154With the development of technology, pure electric vehicles are becoming more and more common, but pure electric vehicles are difficult to get a better solution in terms of cruising range, charging speed, and pollution after battery waste. This mak...
Посмотреть детали -
Летать за мечтой, создавать большую славу, ежегодная церемония [Wuxi Guanya LNEYA] завершилась успешно
1500Inadvertently2019 has passedThis yearThanks to everyone for the trust and support of Guanya LNEYA Eye-catching gloryFrom every step of the solidThank you all the wayDream-seeking career2020 Let us continue to work together for a win-win sit...
Посмотреть детали -
Tips for Leakage Detection of Low Temperature Freezer
1011Soaking leakage detectionThe sensibility of soaking leakage detection is higher than bubble test,which is usually applied for small Freon freezer unit. When using it, the equipment prohibited from contacting water in the system should be discharge...
Посмотреть детали -
Application of Microchannel Reactor Temperature Control System in the Laboratory
902Application of Microchannel Reactor Temperature Control System
Посмотреть детали